beautypg.com

Rebuilding arrays – SUPER MICRO Computer 6014P-TR User Manual

Page 114

background image

B-14

S

UPER

S

ERVER 6014P-T/6014P-TR User's Manual

Rebuilding Arrays

Note 1: Rebuilding applies to Fault Tolerant arrays (RAID 1) only.

If an array build process (or initialization) is interrupted or critical with one member

missing, you must perform a rebuild to optimized its functionality. For a critical

array rebuild operation, the optimal drive is the source drive.

Note 2: If no spare array exists and a hard disk drive fails, you need to

create a spare before you can rebuild an array.

To Rebuild an array:

1. From the Main Menu, select Manage Arrays. From the list of arrays, select

the array you want to rebuild.

2. Press Ctrl+R to rebuild.

6. Press Enter.

7. Read the warning message as shown on the screen below.

8. Make sure that you have selected the correct disk drives to initialize. If cor-

rect, type Y to continue.

This manual is related to the following products: