Star Trac Pro S User Manual
Page 52

50
STAR TRAC PRO S / PRO / PRO ELITE TREADMILL O
WNER
’
S
M
ANUAL
Lowest
Default
Highest
Item
Value
Value
Value
Meaning
ENTERTAIN-
-
OFF
-
ON=Entertainment enabled.
MENT
OFF=Entertainment disabled.
RAIL STOP
-
OFF
-
ON=Enables hardware stop for European units.
OFF=Disables hardware stop for European units.
10 REV
22.0
30.7
74.0
Inches of running belt travel for 10 flywheel revolutions, always measured in
inches. Nominal values are:
■
1.6" pulley: 27.5
■
1.7" pulley: 29.1
■
1.8" pulley: 30.7
■
2.1" pulley: 35.8
CNT/REV
31
31
125
Number of counts for each motor shaft revolution. Values are:
■
RPM sensor at flywheel notches: 31
■
RPM sensor at motor shaft optical disk: 125
MIN PWM
2
30
55
Pulse duty cycle to obtain the selected MN SPD. Divide MN PWM by 512 to
get % duty cycle.
1/2 MX
25
130
170
Pulse duty cycle to obtain 1/2 maximum speed. Divide 1/2 MX by 512 to get %
duty cycle.
MAX PWM
86
230
255
Pulse duty cycle to obtain the selected MX Spd. Divide MX PWM by 512 to get
% duty cycle.
ACCEL TIME
25
25
60
Time, in seconds, to reach maxmium speed from 0 mph (0 km/hr).
DECEL TIME
20
20
60
Time, in seconds, to reach 0 mph (0 km/hr) from maximum speed.
DATE
1.00
1.98
12.99
Treadmill manufacture date.
NO RAIL
0
0
255
Number of times Hand Rail Stop switch was down or disconnected on power-
STOP
up since last reset.
KEY DOWN
0
0
255
Number of times key other than 5 or 8 was down on power-up since last reset.
SPEED CHG
0
0
255
Number of times speed changed suddenly more than 2 mph (UNITS=English)
or 2 km/hr (UNITS=Metric) since last reset.
ELEV STALL
0
0
255
Number of times elevation failed to change (stalled) since last reset.
ELEV RANGE
0
0
255
Number of times elevation was out of range (not between 0% and 15%) at
power-up since last reset.
ELEV LOST
0
0
255
After pressing S
TART
and reaching 0% reset, the number of times elevation
went beyond 0% to 15%, since last reset.
NO MOTOR
0
0
255
Number of times the motor could not verify a load since last reset.
NO SENSOR
0
0
255
Number of time the sensor was inoperable since las reset.
ELEV ZERO
175
240
242
Representation of voltage to elevation motor to obtain 0% elevation. Multiply
ELEV ZERO by 0.019608 to get actual voltage.
ELEV MAX
25
57
170
Representation of voltage to elevation motor to obtain 15% (maximum) eleva-
tion (incline). Multiply ELEV MAX by 0.019608 to get actual voltage.
120 volt treadmill = 57
230 volt treadmill = 80
LAST DECK
0
0
65,535
Number of miles (UNITS=English), or km (UNITS=Metric) since the running
deck was last serviced or replaced.
LAST BELT
0
0
65,535
Number of miles (UNITS=English) or km (UNITS=Metric) since the running
belt was last replaced.
LAST MOTOR
0
0
65,535
Number of miles (UNITS=English), or km (UNITS=Metric) since the motor
brushes were last serviced or replaced.
MASTER PIN
0000
4321
9999
Master Personal Identification Number (PIN) for Personal Trainer.