When the MINIMUM SPD or MAXIMUM SPD parameters are changed, the Treadmill will perform an auto calibration. To ter-

minate the auto calibration and return the parameter to its default setting, press the S

TOP

key.

**

Available on Pro Treadmill only.

MAINTENANCE SETTINGS

Your Service Representative may need to check accumulated data about the past usage of your treadmill, test its motor and dis-
play controls, or investigate error messages. For these reasons, your treadmill is equipped with Maintenance Settings.
Maintenance Settings includes all of the items available through Manager Settings, plus additional items for Service and
Diagnostic use. To enter Maintenance Settings:

1. Press and hold the ,

, and

S

TART

keys together.

2. Release the

key.

3. A beep will sound and “MAINTENANCE SETTINGS” will display momentarily in the Information Window.

4. Release the remaining keys. “UNITS” will display in the Information Window.

The following keys are available in MAINTENANCE SETTINGS:

Incline Keys: Displays the next and previous parameter, respectively. Keys will repeat if held.

Speed Keys: Adjust the value of the displayed parameter up and down, respectively, in increments of 1 unit or
0.01 unit, as appropriate for the parameter. These keys do not save the new value - see Start Key and Enter
Key
below.

2

2

0

48

STAR TRAC PRO S / PRO / PRO ELITE TREADMILL O

WNER

S

M

ANUAL

Lowest

Default

Highest

Item

Value

Value

Value

Meaning

SERIAL NO

0

0

65,535

Treadmill serial number.

LANGUAGE

-

English

-

Language in English, Dutch, French, German, Portuguese, Spanish, Swedish,
Italian or Katakana.

ENTRY

-

Units

-

Speed entry: First character is UNITS, or TENTHS.

METS

-

OFF

-

ON=METS display enabled.
OFF=METS display disabled.

WATTS

-

OFF

-

ON=WATTS display enabled.
OFF=WATTS display disabled.

PAUSE

30

45

120

Pause duration during a program, in seconds, either 30, 45

,

60

, 90 or 120.

SCALE**

-

OFF

-

ON=Treadmill weight scale enabled.
OFF=Treadmill weight scale disabled.

INFRA RED

-

OFF

-

ON=IR communication enabled.

COM**

OFF=IR communication disabled.

CSAFE**

-

OFF

-

ON=CSAFE communication enabled.
OFF=CSAFE communication disabled.

FAN**

-

OFF

-

ON=Treadmill fan enabled.
OFF=Treadmill fan disabled.

AUTO STOP

-

ON

-

ON=Auto stop feature enabled.
OFF=Auto stop feature disabled.

ENTERTAIN-

-

OFF

-

This feature is currently unavailable.

MENT

RAIL STOP

-

OFF

-

ON=Enables hardware stop for European units.
OFF=Disables hardware stop for European units.

LOCKOUT ID

10000

12345

65535

Treadmill lockout ID.

LOCK OUT

-

OFF

-

ON=Treadmill lock out enabled.
OFF=Treadmill lock out disabled.

This manual is related to the following products: