Voltage Conversion

The Model 1824 is prewired for a 220V power supply, but

it can be rewired to operate on a 110V power supply. To

reduce the risk of electrocution, machine damage, or an

electrical fire, this procedure must be performed by an

electrician or qualified service personnel. The procedure

involves moving terminal jumpers inside the motor

junction box, replacing the machine circuit breaker, and

replacing the plug on the power cord.

The require machine circuit breaker can be purchased

from an authorized Shop Fox dealer. The required

plug and receptacle can be purchased from your local

hardware store or it may be provided by your electrician.

Items Needed

Qty

Phillips Screwdriver #2 .........................................1

NEMA 5-20 Plug ..................................................1

Circuit Breaker 20A (Part No. X1824204-1) .................1

To convert the table saw to 110V, do these steps:

1. DISCONNECT TABLE SAW FROM POWER!

2. Open the motor junction box, then loosen the four

screws indicated in

Figure 4.

3. Remove the two center jumpers (they are stacked

together), reposition them as shown in

Figure 5,

then re-tighten the four screws loosened in

Step 2.

4. Close and secure the motor junction box.

5. Remove the START/STOP switch box from the switch

mounting plate.

6. Replace the pre-installed 10A circuit breaker

(see

Figure 6) with the 20A circuit breaker, then

re-install the switch box.

7. Replace the existing power cord plug with a NEMA

5-20 plug, according to the instructions and wiring

diagram provided by the plug manufacturer.

Load

Line

KEDU HY56

20A 250V

35A 125V

Neutral

Hot

Ground

110 VAC

5-20 Plug

(As Recommended)

110V/220V

MOTOR

SWITCH

BOX

Rewired for 110V

Motor Rewired

for 110V

Motor Prewired

for 220V

Start

Capacitor

200MFD

250VAC

Run

Capacitor

60MFD

300VAC

Circuit Breaker (10A

at 220V)

(20A

at 110V)

ON/OFF

SWITCH

Ground

Hot

Hot

6-20 PLUG

220 VAC

Rewired for 110V

Figure 4. Locations of screws to be

loosened.

Center Jumpers

Loosen

These

Screws

Load

Line

KEDU HY56

20A 250V

35A 125V

Neutral

Hot

Ground

110 VAC

5-20 Plug

(As Recommended)

110V/220V

MOTOR

SWITCH

BOX

Rewired for 110V

Motor Rewired

for 110V

Motor Prewired

for 220V

Start

Capacitor

200MFD

250VAC

Run

Capacitor

60MFD

300VAC

Circuit Breaker (10A

at 220V)

(20A

at 110V)

ON/OFF

SWITCH

Ground

Hot

Hot

6-20 PLUG

220 VAC

Rewired for 110V

Figure 5. Relocated jumpers.

New Jumper Locations

Circuit

Breaker

Figure 6. Location of switch circuit

breaker.

This manual was current at the time of printing.

However, if the motor wiring diagram provided on

the inside of the junction box cover differs from this

manual, always use the junction box cover wiring

diagram. This should reflect any changes that may

have occurred after printing.