Table 18: power cord specifications, Table 19: environmental specifications, Table 20: heat dissipation guidelines – Juniper Networks IDP SERIES IDP250 User Manual
Page 72

Table 18: Power Cord Specifications
Specifications
Country
•
UL-approved and CSA-certified
•
Flexible cord minimum spec: No. 18 (1.5 mm2SVT or
SJT, 3-conductor
•
Current capacity of 10A minimum
•
Earth-grounding attachment plug with NEMA 5-15P
(10A, 125V) configuration
United States and Canada
list environmental specifications.
Table 19: Environmental Specifications
Value
Specification
41° to 104° F (5° to 40° C)
Operating temperature
-40° to 158° F (-40° to 70° C)
Storage temperature
8% to 90% noncondensing
Relative humidity (operating)
5% to 95% noncondensing
Relative humidity (storage)
10,000 ft (3,048 m)
Altitude (operating)
40,000 ft (12,192 m)
Altitude (storage)
Heat dissipation rates depend on the traffic rate and the number and type of features
you have enabled.
provides guidelines.
Table 20: Heat Dissipation Guidelines
BTU/hour
Watts
Specification
273
80
Minimum
375
110
Maximum
Copyright © 2012, Juniper Networks, Inc.
60
IDP250 Installation Guide