Refer to Table 13 for an explanation on reason codes for failed program start requests.

Table 1. Reason Codes for Rejected Program Start Requests

Reason
Code

Reason Description

401

Program start request received to a device that is not allocated to an active subsystem.

402

Requested device is currently being held by a Hold Communications Device (HLDCMNDEV) command.

403

User profile is not accessible.

404

Job description is not accessible.

405

Output queue is not accessible.

406

Maximum number of jobs defined by subsystem description are already active.

407

Maximum number of jobs defined by communications entry are already active.

408

Maximum number of jobs defined by routing entry are already active.

409

Library on library list is exclusively in use by another job.

410

Group profile cannot be accessed.

411

Insufficient storage in machine pool to start job.

412

System value not accessible.

413

QSERVER not started

501

Job description was not found.

502

Output queue was not found.

503

Class was not found.

504

Library on initial library list was not found.

505

Job description or job description library is damaged.

506

Library on library list is destroyed.

507

Duplicate libraries were found on library list.

508

Storage-pool defined size is zero.

602

Transaction program-name value is reserved but not supported.

604

Matching routing entry was not found.

605

Program was not found.

704

Password is not valid.

705

User is not authorized to device.

706

User is not authorized to subsystem description.

707

User is not authorized to job description.

708

User is not authorized to output queue.

709

User is not authorized to program.

710

User is not authorized to class.

711

User is not authorized to library on library list.

712

User is not authorized to group profile.

713

User ID is not valid.

714

Default user profile is not valid.

715

Neither password nor user ID was provided, and no default user profile was specified in the
communications entry.

718

No user ID.

722

A user ID was received but a password was not sent.

723

No password was associated with the user ID.

725

User ID does not follow naming convention.

726

User profile is disabled.

730

Password has expired.

801

Program initialization parameters are present but not allowed.

802

Program initialization parameter exceeds 2000 bytes.

803

Subsystem is ending.

804

Prestart job is inactive or is ending.

805

WAIT(NO) was specified on the prestart job entry and no prestart job was available.

806

The maximum number of prestart jobs that can be active on a prestart job entry was exceeded.

807

Prestart job ended when a program start request was being received.

Chapter 8. Troubleshooting communications problems