Intel Server Board S5000PAL User Manual
Page 93
![background image](/manuals/127596/93/background.png)
Appendix B: Sensor Tables
Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision
1.4
Intel order number: D31979-007
94
Sensor
Name
Sensor
Number
System
Applica-
bility
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Criticality
Assert /
De-assert
Readable
Value /
Offsets
Event Data
Rearm
Standby
Sensor
Failure
86h All Sensor
Failure
F6h
OEM
Sensor
Specific
73h
I
2
C device not
found
I
2
C device error
detected
I
2
C bus timeout
OK As
–
Trig
Offset
A X
NMI Signal
State
87h All OEM
C0h
Digital
Discrete
03h
01h – State
asserted
OK –
01h
–
–
–
SMI Signal
State
88h All OEM
C0h
Digital
Discrete
03h
01h – State
asserted
OK –
01h
–
–
–
IERR Critical
Thermal trip
Non-rec
Config error
Critical
Presence OK
Proc 1
Status
90h All Processor
07h
Sensor
Specific
6Fh
Disabled Degraded
As and De
–
Trig Offset
M
X
IERR Critical
Thermal trip
Non-rec
Config error
Critical
Presence OK
Proc 2
Status
91h All Processor
07h
Sensor
Specific
6Fh
Disabled Degraded
As and De
–
Trig Offset
M
X
Proc 1
Temp
98h All Temperature
01h
Threshold
01h
[u,l] [c,nc]
Threshold
defined
As and De Analog
R, T
A
–
Proc 2
Temp
9Ah All Temperature
01h
Threshold
01h
[u,l] [c,nc]
Threshold
defined
As and De Analog
R, T
A
–
Bus correctable
error
OK
PCIe Link0 A0h
Critical
Interrupt
13F
Sensor
Specific
6Fh
PCIe
Link0
Bus
uncorrectable
error
Degraded
As –
See
the
BIOS EPS
A –