4 riser card slots, 3 lcp/aux ipmb header, 4 ipmb header – Intel Server Board S5000PAL User Manual
Page 47
![background image](/manuals/127596/47/background.png)
Connector / Header Locations and Pin-outs
Intel
®
Server Board S5000PAL / S5000XAL TPS
Revision
1.4
Intel order number: D31979-007
48
5.3.3
LCP/AUX IPMB Header
Table 16. LPC/AUX IPMB Header Pin-out (J1C2)
Pin
Signal Name
Description
1
SMB_IPMB_5VSB_DAT BMC IMB 5V Standby Data Line
2 GND
Ground
3
SMB_IPMB_5VSB_CLK BMC IMB 5V Standby Clock Line
4
P5V_STBY
+5V Standby Power
5.3.4 IPMB
Header
Table 17. IPMB Header Pin-out (J1C3)
Pin
Signal Name
Description
1
SMB_IPMB_5VSB_DAT BMC IMB 5V Standby Data Line
2 GND
3
SMB_IPMB_5VSB_CLK BMC IMB 5V Standby Clock Line
5.4 Riser Card Slots
The server board has two riser card slots. The full height riser slot (J4F1) utilizes Intel
®
Adaptive Slot
Technology. It is capable of supporting riser cards that support either the PCI-X* or PCI Express* full
height / full length add-in cards. The low profile riser slot (J5B1) supports riser cards that support low
profile PCI Express* add-in cards. The following tables show the pin-out for these riser slots.
Table 18. Low-profile Riser Slot Pin-out (J5B1)
Pin Side B
PCI Spec Signal
Pin Side A
PCI Spec Signal
1 P12V 1
2 P12V 2 P12V
3 P12V 3 P12V
4 GND 4 GND
5 SMB_PCI3V3SB_CLK 5
PD_LP_TCK
6 SMB_PCI3V3SB_DAT 6
PU_LP_TDI
7 GND 7
FP_CHASSIS_INTRU
8 P3V3 8
PU_LP_TMS
9 PD_LPTRST_N 9
P3V3
10 P3V3_AUX 10
P3V3
11 PE_WAKE_N 11 PE_RST_LP_N
12 P3V3 12 GND
13 GND 13
CLK_100M_LP_PCIE_SLOT1_P
14
PE4_MCH_TXP_C <3..0> 0
14
CLK_100M_LP_PCIE_SLOT1_N
15
PE4_MCH_TXN_C <3..0> 0
15
GND
16
GND
16
PE4_MCH_RXP <3..0> 0
17
17
PE4_MCH_RXN <3..0> 0
18 GND 18 GND
19
PE4_MCH_TXP_C <3..0> 1
19
P3V3