Troubleshooting

SYMPTOM

PROBABLE CAUSE

SOLUTION

LIMITED DRIVING

DISTANCE.

Battery not charged long enough.

Batteries weak, won’t hold

charge.

Charge batteries overnight or ensure eight

(8) hours of charge between use.

Replace batteries. Refer to Removing/

Installing the Battery Box on page 41.

BATTERIES NOT

CHARGING.

Charger not working.

Battery connections loose.

No current at wall outlet.

Bad connection on charger,

charger cable, plug or internal

wiring problem.

Replace charger. Contact Dealer or a quali-

fied technician.

Check all connections. Secure connections.

Refer to Removing/Installing the Battery

Box on page 41.

Switch another wall outlet.

Replace charger or internal repairs

required. Contact Dealer or a qualified

technician.

BATTERIES DRAW

EXCESSIVE CURRENT

WHEN CHARGING.

Battery failure.

Replace batteries. Refer to Removing/

Installing the Battery Box on page 41.

BATTERY INDICA-

TOR SHOWS THE

CHARGE LEVEL IS

LOW - TOO SOON

AFTER BEING

RECHARGED.

Charger not working.

Weak batteries.

Have charger checked. Service or replace

the charger. Contact Dealer or a qualified

technician.

Replace batteries. Refer to Removing/

Installing the Battery Box on page 41.

SCOOTER WILL NOT

DRIVE.

Brake release lever disengaged.

Batteries require charging.

Key not fully plugged in.

Charger plugged in.

Circuit breaker tripped.

Fuse blown in battery box.

Soft stop engaged. If key is turned

off while driving, the scooter

holds power for 1.5 seconds

slowly decelerating to a stop.

Engage brake release lever. Refer to Engag-

ing/Disengaging the Brake Release Lever on

page 27.

Charge batteries. Refer to Charging the Bat-

teries on page 43.

Ensure key is inserted fully into keyswitch.

Unplug charger from scooter.

Reset breaker. Refer to Resetting the Cir-

cuit Breaker on page 28. If breaker trips

again, it may indicate need for internal

repairs. Contact Dealer or a qualified tech-

nician.

Replace fuse. Contact Dealer or a qualified

technician.

With key in the off position, wait for 30 sec-

onds and turn key to the on position.