Diagnostic Error Code
FRU/Action
030-00X-XXX
030-01X-XXX
SCSI interface failure
1.
SCSI signal cable
2.
Check power supply
3.
SCSI device
4.
SCSI adapter card, if installed
5.
System board
030-027-XXX
SCSI interface Configuration/Setup error
1.
SCSI signal cable
2.
Flash the system
3.
SCSI device
4.
SCSI adapter card, if installed
5.
System board
030-03X-XXX
030-04X-XXX
SCSI interface error
1.
SCSI signal cable
2.
Check power supply
3.
SCSI device
4.
SCSI adapter card, if installed
5.
installed System board
030-195-XXX
SCSI interface Test aborted by user
1.
Information
2.
Re-start the test, if necessary
030-196-XXX
SCSI interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
030-197-XXX
SCSI interface test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
030-198-XXX
SCSI interface test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″
section
030-199-XXX
SCSI interface test failed, cause unknown
1.
Go to the
″Undetermined problems″
section
2.
Flash the system and re-test
3.
Replace component under function test
035-000-XXX
RAID interface Test Passed
1.
No action
035-0XX-XXX
RAID interface Failure
1.
RAID signal cable
2.
RAID device
3.
RAID adapter card, if installed
4.
System board
035-195-XXX
RAID interface Test aborted by user
1.
Information
2.
Re-start the test, if necessary
50