IBM A40 TYPE 6840 User Manual
Page 53
Diagnostic Error Code
FRU/Action
015-002-XXX
USB port Timeout
1.
Remove USB device(s) and re-test
2.
System board
015-015-XXX
USB port External Loopback failure
1.
Remove USB device(s) and re-test
2.
System board
015-027-XXX
USB port Configuration/Setup error
1.
Flash the system
2.
System board
015-032-XXX
USB port Device Controller failure
1.
System board
015-034-XXX
USB port buffer
allocation failure
1.
Reboot the system
2.
Flash the system
3.
Run memory test
4.
System board
015-035-XXX
USB port Reset condition detected
1.
Remove USB device(s) and re-test
2.
System board
015-036-XXX
USB port Register error
1.
System board
015-040-XXX
USB port IRQ failure
1.
Run setup and check for conflicts
2.
Flash the system
3.
System board
015-195-XXX
USB port Test aborted by user
1.
Information
2.
Re-start the test, if necessary
015-196-XXX
USB port test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
015-197-XXX
USB port test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
015-198-XXX
USB port test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″
section
015-199-XXX
USB port test failed, cause unknown
1.
Go to the
″Undetermined problems″
section
2.
Flash the system and re-test
3.
Replace component under function test
018-000-XXX
PCI Card Test Passed
1.
No action
018-0XX-XXX
PCI Card Failure
1.
Riser card, if installed
2.
System board
Chapter 6. Symptom-to-FRU Index
47