Diagnostic Error Code

FRU/Action

015-002-XXX
USB port Timeout

1.

Remove USB device(s) and re-test

2.

System board

015-015-XXX
USB port External Loopback failure

1.

Remove USB device(s) and re-test

2.

System board

015-027-XXX
USB port Configuration/Setup error

1.

Flash the system

2.

System board

015-032-XXX
USB port Device Controller failure

1.

System board

015-034-XXX
USB port buffer
allocation failure

1.

Reboot the system

2.

Flash the system

3.

Run memory test

4.

System board

015-035-XXX
USB port Reset condition detected

1.

Remove USB device(s) and re-test

2.

System board

015-036-XXX
USB port Register error

1.

System board

015-040-XXX
USB port IRQ failure

1.

Run setup and check for conflicts

2.

Flash the system

3.

System board

015-195-XXX
USB port Test aborted by user

1.

Information

2.

Re-start the test, if necessary

015-196-XXX
USB port test halt, error threshold exceeded

1.

Press F3 to review the log file

2.

Re-start the test to reset the log file

015-197-XXX
USB port test warning

1.

Make sure the component that is called
out is connected and/or enabled

2.

Re-run test

3.

Component that is called out in warning
statement

4.

Component under test

015-198-XXX
USB port test aborted

1.

If a component is called out, make sure
it is connected and/or enabled

2.

Flash the system and re-test

3.

Go to the

″Undetermined problems″

section

015-199-XXX
USB port test failed, cause unknown

1.

Go to the

Undetermined problems

section

2.

Flash the system and re-test

3.

Replace component under function test

018-000-XXX
PCI Card Test Passed

1.

No action

018-0XX-XXX
PCI Card Failure

1.

Riser card, if installed

2.

System board