IBM A40 TYPE 6840 User Manual
Page 51

Diagnostic Error Code
FRU/Action
011-000-XXX
Serial port Interface Test Passed
1.
No action
011-001-XXX
Serial port Presence
1.
Remove external serial device, if
present
2.
Run setup, enable port
3.
System board
011-002-XXX
011-003-XXX
Serial port Timeout/Parity error
1.
System board
011-013-XXX
011-014-XXX
Serial port Control Signal/Loopback test
failure
1.
System board
011-015-XXX
Serial port External Loopback failure
1.
Wrap plug
2.
System board
011-027-XXX
Serial port Configuration/Setup error
1.
Run Setup, enable port
2.
Flash the system
3.
System board
011-03X-XXX
011-04X-XXX
Serial port failure
1.
System board
011-195-XXX
Serial port Test aborted by user
1.
Information
2.
Re-start the test, if necessary
011-196-XXX
Serial port test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
011-197-XXX
Serial port test warning
1.
Make sure the component that is called
out is connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning
statement
4.
Component under test
011-198-XXX
Serial port test aborted
1.
If a component is called out, make sure
it is connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″
section
011-199-XXX
Serial port test failed, cause unknown
1.
Go to the
″Undetermined problems″
section
2.
Flash the system and re-test
3.
Replace component under function test
011-2XX-XXX
Serial port signal failure
1.
External serial device
2.
System board
014-000-XXX
Parallel port Interface Test Passed
1.
No action
Chapter 6. Symptom-to-FRU Index
45