beautypg.com

IMC Networks iMcV-Giga-FiberLinX-II User Manual

Page 37

background image

33

d. Enter the management tag (VLAN ID) and the priority (optional).

Is a VLAN tag required on Management packets? [ Y ]
The Management Tag is [7 ]
Management Priority is [0 ]

e. Ensure the Are VLAN Tags required on the EXT Port? field is set to

N.

Are VLAN Tags required on the EXT Port? [ N ]

f. Press S or F3 to save the settings. This will set all traffic with VLAN ID 7 as

management.

g. Type reboot.

Now the iMcV-Giga-FiberLinX-II is configured to pass all data between the OPTICS
(UPLINK) and DATA ports, except data tagged with VLAN ID 7. All data tagged with
VLAN ID 7 is considered management traffic and passes from the OPTICS (UPLINK)
port to the EXT MGMT port only. The iMcV-Giga-FiberLinX-II is configured to
receive untagged data from the twisted pair EXT MGMT port and add the VLAN ID 7
before sending it out of the OPTICS (or UPLINK) port. In this mode the EXT MGMT
port provides a secure link to the management port at the other end of the fiber line.

DATA:

Off

Untagged Data and Tagged Data
(without management-VLAN #7)

EXT MGMT:

On

Management

OPTICS:
Untagged Data, Tagged Data
including management with
VLAN ID = 7

On

Port

SNMP

DIP Switch

Settings

1-EXT MGMT=ON
2-DATA=OFF
3-OPTICS=ON