IMC Networks iMcV-Giga-FiberLinX-II User Manual
Page 30
26
Configuration screen, press the space bar, type unit, and press Enter to open the Unit
Control Settings screen. In this screen you can view the unit FlowControl,
FiberAlert/LinkLoss, Loopback, Maximum Frame Size, and 802.1p Base Priority
(logging-in as a User in a Telnet session allows you to view these settings but prevents
you from changing the settings).
------------------------- Unit Control Settings -----------------------------
nit FlowControl
Disable FlowControl Globally
U
nit FiberAlert
TXLinkLoss Plus FXLinkLoss Enabled
U
nit LoopBack
No LoopBack, Normal Traffic Mode
U
nit Max FrameSize
1526
U
02.1p Base Pri
Base Priority 4
8
oot Trap Deplay, Seconds
0
B
B
ange Value.
Use
Arrow Keys
To Move Cursor. Press
Space ar
To Ch
Press
RETURN
To Set New Value. Type
Q
or
F4
to Exit.
Unit FlowControl–This allows you to enable/disable Flow Control functionality on
the unit. You must enable this to use Flow Control on any port. The settings include
the following:
• Disable FlowControl Globally
• Enable FlowControl If Port Allows
Unit FiberAlert–This allows you to enable/disable FiberAlert and LinkLoss
functionality on the unit. The settings include:
• No FiberAlert Or LinkLoss Enabled
• FXLinkLoss Only, Enabled
• TXLinkLoss Only, Enabled
• FiberAlert Plus FXLinkLoss Enabled
• FiberAlert Plus TXLinkLoss Enabled
• TXLinkLoss Plus FXLinkLoss Enabled
• TXLinkLoss + FXLinkLoss + FiberAlert Enabled
• FiberAlert Only
Unit LoopBack–enable/disable Loopback functionality on the unit. The settings
include the following:
• No LoopBack, Normal Traffic Mode
• LoopBack Enabled
• LoopBack, Src/Dest Address Swap
• LoopBack, Address Swap, Clear Multicast bit
• No Learning on OPTICS (or UPLINK) or DATA Ports