SX-200 General Information Guide

214

Revision A

50003510

Site

SX-200 IP Node

Temperature

0º C to 40º C (32º F to 104º F)

Humidity

15 to 95% Relative Humidity, non-condensing

Vibration

0.5 g, 5 to 100 Hz, any orthogonal axis
1.5 g, 100 to 500 Hz, any orthogonal axis

Mechanical
Stress

One 15.3 cm (6 in.) drop, each edge and corner adjacent to the rest face –
unpackaged
One 76.2 cm (30 in.) drop, each edge and corner packaged in
cardboard & foam.

Site Conditions

SX-200 EL/ML System

Operating Temperature

0 to 40º C

32 to 104º F

Relative Humidity (Operating)
(non-condensing)

20 to 80%

20 to 80%

Heat Dissipation (approximate)

500 BTUs / hr

Maximum Altitude

4000 m

13,000 ft.

SX-200 IP Node

Operating Temperature

15º to 35º C

59º to 95º F

Relative Humidity (Operating)
(non-condensing)

40 to 90%

Heat Dissipation - fully loaded*

724 BTUs/hr

Air Flow

150 cubic feet per minute at
maximum output of the fans

Acoustic Emission

Maximum 50 dBA continuous, 75
dB intermittent (<10% duty cycle)

* Conversion factors: 1 watt is equal to 3.412 BTUs per hour, 1 ton of refrigeration is equal to 12,000
BTUs per hour or 3.516 Kilowatts, and 3/4 Kilowatt-hour is equal to 1 ton of refrigeration

Storage Conditions (continued)

Specification

Range