3.4.6 Operations and Maintenance Commands
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Upgrade Slot
USI=
1 bytes, value
of 0,1 or 2
Command or Query.
Slot to upgrade new IP firmware where,
0= Oldest
1=Image 1
2=Image 2
Example: UPS=0
USI =
USI!
USI?
USI=x
(see description of
arguments)
Software
Revision
N/A
34-37 bytes
Query only.
Unit returns the value of the internal software revision installed in
the unit, in the form :
Example:
>0001/SWR=Boot:1.1.1 Bulk1:1.5.1u Bulk2:1.5.1P
SWR!
SWR?
SWR=Boot:x.y.zz
Bulk1:x.y.zz
Bulk2:x.y.zz
(see description