Digital io, Dio monitor – Moxa Technologies NE-4100 User Manual
Page 55
NE-4100 Series User’s Manual
Web Console Configuration
6-20
Trap
Setting
Factory Default
Necessity
Enable, Disable
Disable
Optional
This feature helps the administrator manage the NE-4100. NE-4100 sends SNMP Trap to a
pre-defined SNMP Trap server when the enabled events—such as Cold start, Warm start,
Authentication failure, etc.—occur. To configure this feature, you need to click on the event type
box.
DCD changed and DSR changed events are only supported by those models that have these two
signals.
Digital IO
Click on the Digital IO link on the left side of the screen to open the DIO Settings window.
There are 2 options for selecting DIO modes: IN and OUT. When you set the mode to IN, you
will not be able to set the Status to H or L. You can only monitor the DIOs’ status. But when you
set the mode to OUT, you can configure the Status to H or L. Make necessary changes to the
settings and click on submit to validate the modifications.
Refer to Chapter 8 for information about the SW Reset Function.
DIO Monitor
You can monitor the DIO status from the web page shown below. To do so, click on the DIO
Monitor link on the left side of the screen to open the DIO Monitor window.