1. First, use the DI/O selectable jumper to set the DI/O modes, as shown below.
DI DO
0
1
2
3
DI/O Mode
2. After the DI/O modes are set, use the Digital Input Dip Switches to configure the status for
DI0 and DI2. You can either configure the status to “Low” or “High.” If you wish to
configure DI0’s status to “Low” and DI2’s status to “High,” set Dip Switch 1 to the “ON”
position and DIP Switch 3 to the “OFF” position, as shown below.
1
2
3
4
ON
D I P
Digital Input
0
1
2
3
ON: Low
OFF: High
3. DO1 and DO3’s status must be configured with the Web Console. If you configure
DO1’status to “Low” and DO3’s to “High,” the DO1’s LED will show solid red, and DO3’s
LED will not light up. Refer to chapter 6 for more configuration details.
Digital Output
DO0 DO1 DO2 DO3
: Low
: High
Digital Output LEDs
Digital Output LED Circuit Design
The figure shown below is the digital output LED circuit design. The design is called “Sink.”
3.3V
Dout
For developing your own applications, you need to be aware of the voltage limits shown below.
The output electric circuit is 1 mA
Min.
Max.
Unit
Conditions
Low-level
Input Voltage
Maximum voltage when DI is set
to “Low” status.
----- 0.3xVCC
V
High-level
Input Voltage
Minimum voltage when DI is set
to “High” status.
0.7xVCC -----
V
Low-level
Input Voltage
Maximum voltage when DO is set
to “Low” status.
----- 0.4 V
High-level
Input Voltage
Minimum voltage when DO is set
to “High” status
2.4 ----- V
Digital Output’s output current carries only 1 mA.