Udp mode – Moxa Technologies NE-4100 User Manual
Page 50
NE-4100 Series User’s Manual
Web Console Configuration
6-15
The “Destination IP address” parameter can use both IP address and Domain address. For some
applications, the user may need to send the data actively to the remote destination domain address.
TCP connection on
Setting
Factory Default
Necessity
Start up,
Any Character
Start up
Optional
Start up: Attempts to establish a TCP connection as soon as the NE-4100 Series is powered on.
Any Character: Attempts to establish a TCP connection as soon as the NE-4100 Series starts
receiving serial data.
UDP Mode
Delimiter 1
Setting
Factory Default
Necessity
00 to FF
“0” for None
Optional
Delimiter 2
Setting
Factory Default
Necessity
00 to FF
“0” for None
Optional
Once the NE-4100 receives both delimiters through the serial port, it immediately packs all data
currently in its buffer and sends it to the NE-4100’s Ethernet port.
Note: Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer.
Delimiter 2 is optional. If left blank, then Delimiter 1 alone trips clearing of the buffer. If the size of
the serial data received is greater than 1K, the NE-4100 will automatically pack the data and send it to
the Ethernet. However, to use the delimiter function, you must at least enable Delimiter 1. If Delimiter
1 is left blank and Delimiter 2 is enabled, the delimiter function will not work properly.