NE-4100-ST Starter Kit
1
2
3
4
ON
D I P
NE-4100T Series
Module
Attaching NE-4110 Series to the Evaluation Board
J1, J2 on the NE-4110 module and J9, J10 on the evaluation board are for communications
between the NE-4110 Series modules and the evaluation board. Connect Jumper 1 (J1) on the
NE-4110 Series module to Jumper 9 (J9) on the evaluation board, and Jumper 2 (J2) on the
NE-4110 Series module to Jumper 10 (J10), as shown below.
1
2
3
4
ON
D I P
9 10
13 14
1 2
1 2
1
2
1
2
9
10
13
14
Pin 1
Pin 1
NE-4110-ST Starter Kit
NE-4110 Series
Module
Attaching NE-4120 Series to the Evaluation Board
J1, J2 on the NE-4120 module and J9,J10 on the evaluation board are for communications
between the NE-4120 Series modules and the evaluation board. Connect Jumper 1 (J1) on the
NE-4120 Series module to Jumper 9 (J9) on the evaluation board, and Jumper 2 (J2) on the
NE-4120 Series module to Jumper 10 (J10), as shown below. And then connect Jumper 3 (J3) and