beautypg.com

2 at command descriptions 8-10, 2 at command descriptions – MITSUBISHI ELECTRIC MIM-G01 User Manual

Page 44

background image

8.2.2

AT Command Descriptions

This chapter describes the most important AT commands of the modem. The values marked
with an asterisk (*) are the default values.

+TFORMAT - Sets the data format

Sets the data format of the serial interface.

+TFORMAT="

Dataformat

"

Dataformat

:

DatabitsParityStopbits

Databits

:

8, 7

Parity

:

N (none), O (odd), E (even), X (auto-detection, default)

Stopbits

:

1, 2

+TBAUD - Set the baudrate

Sets the baud rate of the serial interface.

+TBAUD="Baudrate"

Baudrate: AUTO (default), 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200,
230400

&K - Select Serial Port Flow Control

This command specifies the DTE-to-modem flow control. Software flow control uses the charac-
ters XOFF (13h) and XON (11h) to stop and start data transmission, respectively, both to and
from the DTE. Bidirectional hardware flow control uses RTS/CTS to stop and start data from the
modem

&K0

Disables flow control

&K3*

Bi-directional hardware flow control - RTS/CTS

&K4

XON/XOFF software flow control

&D - DTR (Data Terminal Ready) Option

This command controls how the modem responds to DTR. After toggling DTR, the host should
wait 200 ms before modifying the UART registers or sending a new command to the modem.
This is done because the modem does not send an ‘OK’ message to indicate it has performed
the requested function.

&D0

The modem ignores DTR.

&D1

The modem switches from data to command mode when an on-to-off transition of DTR occurs.

&D2*

An on-to-off transition of DTR causes the modem to go on-hook (hang up). While DTR
is off, auto-answer is disabled.

&D3

An on-to-off transition of DTR reinitializes the modem. The reinitialize procedure performs the
same function as a power-up reset, except that the UART registers are not reconfigured.

AT Commands MIM-A01

Appendix

8 - 10

MITSUBISHI ELECTRIC

Command

Description

&Z

Store telephone number (up to 30 digits) to location 'n' (0-3)

%E

Auto-retrain control

%G

Rate renegotiation

-C

Generate data mode calling tone

+ES

Error control selection

+MS

Modulation selection

*NC

CallerID settings

+VCID

Country code setting

@D

Accept a new firmware image to flash

Tab. 8-23: Overview of AT Commands (2)

This manual is related to the following products: