3 plc connection 6-4, Plc connection 6-4 – MITSUBISHI ELECTRIC MIM-G01 User Manual
Page 26
6.1.3
PLC Connection
Connect the RS232 jack to the ALPHA XL, using the GSM-CAB. If done so, plug the power
supply into the appropriate terminal.
NOTE
Make sure the SIM card is inserted correctly and power on both the devices. In case the PIN
is set correctly, the MIM-G01 will connect to the PLC and logs onto the GSM network.
The Modem is now ready to send messages. As soon as a GSM feature of the PLC project is
activated, the Modem dials into the SMSC provided and sends the display content as SMS.
(Detailed information is to be found within the Mitsubishi Communication manual.)
In case the modem type does not exist in the selection list of the GSM and serial communica-
tion of the SW0D5-ALVLS-EUL software, it must be added manually.
Therefore select New as modem type. Then click on Initialize Modem... and within the next
dialog, enter this string for modem init:
MIM-G01
ATE0S0=2&S0;+IFC=0,0;+CMEE=1;+IPR=9600;+CICB=0;&W
MIM-A01
ATE0S0=2Q1+D0\Q0\J0&W
NOTE
The entered initialize command may not be displayed in full length in the input area.
Click on OK to return to the previous dialogue and continue configuration, as described in 6.1.1.
MIM and Mitsubishi ALPHA XL
Configuration
6 - 4
MITSUBISHI ELECTRIC
Fig. 6-5:
Initialisation of a GSM Modem