Outdoor unit model

MUZ-FD09NA MUZ-FD12NA

Capacity

Rated (Minimum~Maximum)

Cooling 1

Btu/h

9,000 (2,800~9,000)

12,000 (2,800~12,000)

Heating 47 1

Btu/h

10,900 (3,000~18,000)

13,600 (3,000~21,000)

Capacity Rated

Heating 17 2

Btu/h

12,500

13,600

Power consumption

Rated (Minimum~Maximum)

Cooling 1

W

650 (160~650)

960 (160~960)

Heating 47 1

W

750 (150~2,400)

980 (150~2,400)

Power consumption Rated

Heating 17 2

W

1,730

1,780

EER

1

[SEER]

3

Cooling

13.8 [23.0]

12.5 [22.0]

HSPF IV (V)

4

Heating

10.55 (7.4)

10.55 (7.4)

COP Heating

1 4.26

4.07

Power supply

V , phase , Hz

208/230 , 1 , 60

Max. fuse size (time delay)

A

15

Min. circuit ampacity

A

12

Fan motor

F.L.A

0.56

Compressor

Model SNB130FQAH

R.L.A 8.6
L.R.A 10.8

Refrigerant control

Liner expansion valve

Sound level

1

Cooling dB(A)

48

48

Heating dB(A)

49

49

Defrost method

Reverse cycle

Dimensions

W

in.

31-1/2

D

in.

11-1/4

H

in.

21-5/8

Weight Ib.

80

External fi nish

Munsell 3Y 7.8/1.1

Remote controller

Wireless type

Control voltage (by built-in transformer)

VDC

12 - 24

Refrigerant piping

Not supplied

Refrigerant pipe size

(Min. wall thickness)

Liquid in.

1/4

(0.0315)

Gas in.

3/8

(0.0315)

Connection method

Indoor Flared
Outdoor Flared

Between the indoor &

outdoor units

Height difference

ft.

40

Piping length

ft.

65

Refrigerant charge (R410A)

2 lb. 9 oz.

Refrigeration oil (Model)

NE022

NOTE

: Test conditions are based on ARI 210/240.

1 : Rating conditions (Cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, (75˚FWB) Rated frequency

(Heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 47˚FDB, 43˚FWB Rated frequency

2 :

(Heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 17˚FDB, 15˚FWB Maximum

frequency