beautypg.com

MITSUBISHI ELECTRIC MUZ-FD09NA- U1 User Manual

Page 26

background image

26

I Check of outdoor fan motor

J Check of power supply

Is the outdoor fan motor normal?

(Refer to 10-4.)

Replace the outdoor fan motor.

Disconnect CN932 from the inverter P.C. board, and

measure the resistance of the outdoor fan motor.

Replace the inverter P.C. board.

No

Yes

Is there voltage 208/230 VAC

between the indoor terminal

block S1 and S2?

No

Yes

Replace the indoor

electronic control P.C.

board.

Rectify indoor/outdoor

connecting wire.

Yes

If light up, OK.

If fl ash, refer to 10-3.

Does POWER lamp on the indoor

unit light up?

Dose LED on the inverter P.C.

board light up or fl ash? (Refer

to 10-6.1.)

No

Replace the inverter

P.C. board.

Is there voltage 280 ~ 370 VDC

between DB61 (+) and DB61 (–) on

the inverter P.C. board?

(Refer to 10-6.1.)

No

Check the electric parts in main circuit.

Yes

Yes

No

Disconnect the connector (CN61)

between compressor and intelligent

power module.

Turn ON power supply and press

EMERGENCY OPERATION switch.

Inverter P.C. board

(Solder side)

DB61

280 ~ 370 VDC