PAGE 62 — DA7000 SERIES GENERATORS• OPERATION AND PARTS MANUAL — REV. #5 (01/20/11)

NAMEPLATE AND DECALS ASSY.

36

3

IDLE CONTROL

0

0

0

0

0

HOURS

ON

OFF

WHISPERWATT

7KW AC

Model DA-7000SS

7000 WATT

DIESEL POWERED

AC GENERA

TOR

STARTER SWITCH

RUN

HEAT

START

STOP

HOUR METER

AC VOLTMETER

AC CIRCUIT
BREAKER

16

22

10

9

33

13

30

2

11

29

WHISPER

WATT

7000

TM

32

31

28

6

20

7

5

25

FRONT VIEW

REAR VIEW

GROUND

S-1123

GROUND

S-3821

for G.F.C.I

G.F.C.I.

D92200100

S-2

090

8

S-2

091

FUEL

DRAIN

S-3060

COOLANT

DRAIN

S-1

40

4

OIL

DRAIN

S-1

40

3

CAUTION

S-

14

06

CLE

AN

OR

RE

PLA

CE

PA

PE

R

EL

EM

EN

T

EV

ER

Y

100

HO

UR

S

4

CAUTION

S-1409

DO

NOT

OPERA

TE

WITH

DOORS

OPEN

AC POWER OUTPUT

A55200000A

25A

25A

120V/240V

25A

20A

120V

ON

ON

FUEL COCK

CAUTION

OIL LEVEL

DIPSTICK

H

L

Before starting the engine, check that the oil
level is within the indicated operating range.
If the level is above the

or below

the

, it is important to correct before

operating to avoid damage to the engine.

H

L

mark

mark

27

GROUND ROD

FOR EARTH

GROUND

GE

NE

RA

TO

R

GRO

UN

D

LUG

CONNECT TO

BUILDING

GROUND

(OPTION)

8 FT. MINIMUM

REFERENCE

NEC 250-52(C)

DANGER

THE POSSIBILITY EXISTS OF

IF

GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR G.F.C.I. GROUND TERMINAL.

ELECTROCUTION

G.F.C.I

GROUND

STUD

GROUND

CABLE

#8 MINIMUM

FOR FURTHER GROUNDING

INSTRUCTIONS, READ MANUAL

D93110000

34

Before connecting this generator to any building’s
electrical system, a licensed electrician must install
an isolation [transfer] switch.

Serious injury or death may result without this
transfer switch.

WARNING!

23

A555000103

1. Check the oil level.

2. Check the water level.

3. Check the fuel level.

4. Turn the Idle Control switch to “ON”.

5. Insert the key into the Starter Switch.

6. Turn the key to “RUN”. The Charge

Warning lamp and the Oil Pressure Warning lamp

should be lit.

7. Turn the key to “HEAT”. When the preheat lamp

lights turn the key to “START” to start the engine.

AVOID HIGH SPEEDS IMMEDIATELY AFTER

STARTING.

8. When the engine starts, the Oil Pressure

Alarm lamp should go out.

9.

10.

Let the engine idle for more than 5 minutes

with the Idle Control switch in “ON” position.

Check the engine for abnormal vibrations noise

and oil leakage.

11. Turn the Idle Control switch to either “ON” or

“OFF” for full engine operation.

12. After generating let the engine run for 5 minutes

with the Idle Control switch in the “ON” position.

NEVER STOP THE ENGINE SUDDENLY EXCEPT

IN AN EMERGENCY.

13. Stop the engine by turning the key in the

Starter Switch to “STOP” and remove the key.

OPERATING PROCEDURE

MULTIQUIP WhisperWatt
AC Generator

17

MODEL

SERIAL

NO.

DANGEROUS
GAS

S-4984

WARNING

Only operate machine in well ventilated
areas.
DO NOT inhale exhaust gases.

Only qualified personnel should
install, use or service this
equipment.

S-4985

DANGER

Do not

touch

output

terminals

or

internal

wiring

while

unit is o

perating.

Turn

off power

before

servicing.

Only

qualified

personnel

should

install,

use

or service

this

equipment.

ELECTRICAL
SHOCK
HAZARD

15

14

CAUTION

HOT PARTS can burn skin.

DCL181

DO NOT touch until the
machine has sufficiently
cooled.

18

WARNING

MOVING PARTS can cause
severe injury.

DCL182

DO NOT operate with
doors open.
Stop engine before
servicing.

19

WARNING

HOT COOLANT can cause
severe burns.

DCL183

DO NOT remove cap if
radiator is hot.

USE #2 DIESEL
FUEL ONLY

S-1408

COOLING

WATER

S-3061

12

AC CIRCUIT
BREAKER

AC CIRCUIT
BREAKER

O

FF

O

FF

2

2

A
2

2

A

120

120

V

20A

120V

120V

OFF

OFF

ON

GA-2.9R

GA-2.9R

2900

DANGER

Using a generator indoors

.

CAN KILL YOU IN MINUTES

Generator exhaust contains carbon monoxide. This is
a posion you cannot see or smell

NEVER use inside a home
or garage, even if doors
and windows are open

AC CIRCUIT
BREAKER

AC CIRCUIT
BREAKER

O

FF

O

FF

2

2

A
22A

120

V

20A

20A

120V

120V

OFF

OFF

ON

GA-2.9R

GA-2.9R

2900

AC CIRCUIT
BREAKER

AC CIRCUIT
BREAKER

O

FF

OF

F

2

2

A
2

2A

120

120

V

20A

20A

120V

120V

OFF

OFF

ON

GA-2.9R

GA-2.9R

2900

Only use OUTSIDE and
far away from windows,
doors, and vents.

Avoid other generator hazards.

.

READ MANUAL BEFORE USE

1

H
L

CAUTION

DCL194

RESERVE

TANK

WATER

COOLANT

LEVEL

1. Maintain water/coolant level

at

of radiator coils.

2. Maintain reserve tank water/

coolant level between H and
L mark. Use a mixture of
50/50 Anti-Freeze/Water.

3. Add coolant when reserve

tank is low (L). Fill to the H
mark with Anti-Freeze/Water.

top

CHECK DAILY

DANGER

Cigarettes, flames or sparks could cause battery to explode. Always
shield eyes and face from battery. Do not charge or use booster cables
or adjust post connections without proper instruction and training.

EXPLOSIVE GASES

KEEP VENT CAPS TIGHT AND LEVEL

POISON

CAUSES SEVERE BURNS

Contains sulfuric acid. Avoid contact with skin, eyes or clothing. In
event of accident flush with water and call a physician immediately.

KEEP OUT OF REACH OF CHILDREN

24

FUSE PULLY

USE

SPECIFIED

F

USE

ONL

Y

.

5A

F

F

15A

F

5A

F

5A

F

5A

F

30A

6

5

4

3

2

1

SP
ARE

15A

30A

26

35

DECAL

KIT

ON

ON

FUEL COCK

COOLING

WA

T

E

R

S

-3

0

6

1

S

-1

4

0

8

USE

#2

DIESEL

FUEL

ONL

Y

37

G.F.C.I.

D92200100

22