beautypg.com

MTD -ERV 350 User Manual

Page 45

background image

4

41

Instructions for the Installer

A8

Malfunction

Frost protection element gets too hot

Remove the filter,

the plastic front cover and

the metal cover

Does the frost protection

element flap work properly?

(Check with P76)

Yes

Check the following factors:
- Fan settings (too low?)
- Supply air valves (opened too wide?)
- The entire duct system (blockage?)

No

See A5 / A6 Malfunction

section “Initiate self-test”

A7

Malfunction

Frost protection element does

not warm up (sufficiently)

Remove the plug

from the socket

Remove the filter,

the plastic front cover and

the metal cover

Remove the plug of frost

protection element from the PCB

Is the resistance

of the plug of the frost

protection element

> 300 ohm?

Yes

Remove the heat exchanger and

the frost protection element

(and also the foam part in case

of right-hand version)

Is the resistance of

the cable of the frost

protection element

infinite?

Yes

If fuse is blown,

replace cable

No

Is resistance

of T1 OK?

No

Yes

Replace T1

temperature sensor

Replace the PCB

No

Check resistance of the cable

and check connections with the

frost protection element

CAUTION!

Avoid contact with the

PCB and frost protection

element due to risk of

electrocution

CAUTION!

Avoid contact with the

PCB and frost protection

element due to risk of

electrocution

This manual is related to the following products: