Note:
Only for systems with a remote
control switch.

Deactivation delay
for ventilation position 3 (with "

").

• When

"

Time delay values

Sub-menu

Description

Minimum Maximum Default

setting

Menu P9 ! Status of the functions (from menu P5)

Ventilation functions

Sub-menu Description

Activated / not activated

P90

Chimney
sweep control active?

Yes (1) / No (0)

P91

Bypass open (=yes)
/ closed (=no)?

Yes (1) / No (0)

P92

(Option)*

Valve of the geothermal heat
exchanger open (=yes)
/ closed (=no)?

Yes (1) / No (0)

P93

(Option)*

Post-heater active?

Yes (1) / No (0)

P94

(Option)*

0 – 10 V control active?

Yes (1) / No (0)

P95

Frost protection
(standard or preheater) active?

Yes (1) / No (0)

P96

(Option)*

Extractor
hood control active?

Yes (1) / No (0)

P97

Moisture control active?

Yes (1) / No (0)

2

12 Instructions for the User

P26

Note:
Only for sys-
tems with a
remote con-
trol switch.

Deactivation delay for ventilation position 3 (with "

").

When
"

" is pressed BRIEFLY (< 2 sec.),

the MTD-ERV 350 switches to the
HIGHEST LEVEL for ‘x’ minutes and
then switches back automatically to
the set level. ‘x’ can be set between 1
and 20 minutes.

1 Min.

20 Min.

10 Min.

" is held depressed (> 2 sec.), the MTD-ERV 350

switches to the HIGHEST LEVEL for 'x' minutes and then
switches back automatically to the set level. ‘x’ can be set
between 1 and 120 minutes.

1 Min.

120 Min.

30 Min.

P29

(Option)*

Setting the Levels for the Extractor Hood.

When the extractor hood is switched on, the ventilation
levels for the extractor hood can be set a few percent
higher than the corresponding 'normal' ventilation levels.

1%

99%

10%