beautypg.com

3 mtd-erv 350 – MTD -ERV 350 User Manual

Page 22

background image

18 Function of the System

A

C

D

D

C

C

C

I

L

K

J

G

H

2

B

E

E

F

H

1

3.3 MTD-ERV 350

The MTD-ERV 350 consists as standard of the following components:
·

Outer casing (A) of coated sheet steel.

·

Inner lining (B) of high-quality expanded polypropylene (E)PP.

·

4 rotatable air-side connections (C) for the air ducts.

·

2 G3 fi lters (D) for air fi ltration.

·

2 energy-saving DC motors (E) with high-speed impeller.

·

(High-effi ciency) heat exchanger (with optional moisture exchanger) (F) with a thermal effi ciency ex-
ceeding 95% in which moisture as well as heat is recovered from the exhaust air.

·

CC Ease operating unit (G) for reading off data and for settings.

·

PCB panel (H2) with connections for the CC Ease operating unit, the enthalpy exchanger and the sen-
sors with 0 - 10 V controller (2x).

·

PCB panel (H1) with connections for the fans, bypass, preheater, temperature sensors (T1 to T4), 3-po-
sition switch with or without malfunction and fi lter display (option) and the bathroom switch (option).

·

Identifi cation plate (I) with the data on the MTD-ERV 350 (not visible).

·

Condensation drain (J) for discharging the condensation from the warm exhaust air.

·

Sticker (K) with the air connections (not visible).

·

230 V plug (L).

3

This manual is related to the following products: