beautypg.com

MTD -ERV 350 User Manual

Page 43

background image

4

39

Instructions for the Installer

E3

Extractor hood temperature

sensor too high.

Resistance OK?

Yes

No

Replace PCB

Caution:

Reset unit!

Replace

temperature sensor

Caution!

Avoid contact with the

PCB and frost protection

element due to risk of

electrocution

Is something

cooking on the hob?

Yes

No

Turn hob off and

remove item from

heat source

Caution!

Avoid contact with the

PCB and frost protection

element due to risk of

electrocution

E A1

Moisture sensor registers >60%

relative humidity in exhaust air.

Consult the user;

fit standard heat exchanger??

E A2

Cannot read out moisture

sensor

Resistance

OK?

Yes

No

Replace PCB

Caution:

Reset unit!

Replace

temperature sensor

Caution!

Avoid contact with the

PCB and frost protection

element due to risk of

electrocution

Connection

between sensor

and PCB OK?

Yes

Check sensor

resistance

No

Repair

connection

E4

MTD-ERV 350 switched off

via external switch

Cause depends on unit

connected to the MTD-ERV 350:

check the connected unit.