3 testing your installation, 1 pre-power testing, 2 post-power testing – Motorola MotoWI4 PTP 600 Series User Manual
Page 168: Testing your installation, Pre-power testing, Post-power testing

166
11.3 Testing Your Installation
If you have followed the above instructions you will have wired your system to the following
diagram:
Figure 99 - Simplified Circuit Diagram (Only One Transtector Shown For Clarity)
11.3.1 Pre-Power
Testing
Before plugging in the RJ45 to the PIDU check the impedances at the RJ45 as described in
11.3.2 Post-Power
Testing
The Correct Operation is as follows
1. Connect the RJ45 to the PIDU and apply power to the PIDU, the power LED should
illuminate continuously.
2. 45 seconds after powering, the Ethernet LED should be observed starting with 10 slow
flashes.
3. If there is a network connection the Ethernet LED will then show Ethernet activity.
The Ethernet LED does not flash 10 times
Failure of the Ethernet LED to illuminate can be due to wiring to pins 4&5 and 7&8 being
incorrect, for example if the wiring to pins 4 and 7 are crossed.