3 configuration manager program, 4 diagnosing problem using ip utilities – Garmin HM210DP/DI User Manual
Page 114
Troubleshooting
106
EN/LZT 108 6492 R2 - October 2003
14.3
Configuration Manager Program
Indication/Symptom
Troubleshooting Suggestion
I forgot/lost my
Configuration Manager
Username or Password.
If you have not changed the password from the
default, try using root as both the Username and
Password.
Otherwise, you can reset the device to the default
configuration by pressing the Reset button on the
back panel of the device (using a pointed object
such as a pen tip). Then, type the default Username
and password as shown above.
WARNING: Resetting the device removes any
custom settings and returns all settings to their
default values.
I cannot access the
Configuration Manager
program from my browser.
Use the PING utility to check whether your PC can
communicate with the HM210dp/di’s LAN IP
address (by default 192.168.1.1). If it cannot, check
the Ethernet cabling.
Verify that you are using Internet Explorer v5.0 or
later, or Netscape Navigator v6.1 or later. Support
for Javascript
must be enabled in your browser.
Support for Java
may also be required.
Verify that the PC’s IP address is defined as being
on the same subnet as the IP address assigned to
the LAN port on the HM210dp/di.
My changes to
Configuration Manager are
not being retained.
Be sure to use the Commit function after any
changes.
14.4
Diagnosing Problem Using IP Utilities
14.4.1
How to use WINIPCFG
This utility is used mainly to view, release and renew you PCs IP address
configuration.
Use WINIPCFG if your PC is running Windows 95, 98 or Me: