Cpc060*1d (s, Iring, Iagram – Goodman Mfg SS-CPC36-72 User Manual

Page 37: Warning, Roduct, Pecifications, Ingle, Hase, Irect, Rive

background image

36

www.goodmanmfg.com

SS-CPC36-72

SS-CPC36-72

www.goodmanmfg.com

37

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

iring

d

iagram

CpC060*1d (s

ingle

p

hase

, d

ireCt

d

rive

)

Wiring is subject t

o chang

e. Alw

ay

s

re

fer

to the wiring diagr

am or the

unit

for the mos

t up-t

o-da

te

wiring.

W

arning

High

Volt

ag

e:

Disc

onn

ect

all

po

w

er

be

for

e

ser

vicing

or

in

st

alling

this

unit.

Multiple

po

w

er

sour

ces

ma

y

be pr

esen

t. F

ailur

e

to do

so ma

y

cause pr

operty

damag

e,

per

sonal

injur

y,

or dea

th.

H

C

RD

RD

1

RCCF

T

PU

CONTROL

BR

C

2

T1

4

S

T1

GR

BK

5

O

1

YL

4

BR

1

BR

T1

BK

9

RD

COMP

RD

R

BR

3

RCCF

L

T2

3

C

W2

BL

BK

T

Y1

PLF 1

3

T

YL/PK

PU

6

F

BL

3 6

7

5

PU

T3

G

T2

COMPONENT LEGEND

BL

L1

SUPPLY VOLTAGE

CM

BK

R

EM

/

L1

4

C

RD

YL

6

0

C

CM

COMP

EM

GND

LVJB

PLF

RCCF

TB1

TR

3

WH

1

C

A

1

GR

CM

24V

W1

PLF2

YL

8

E

RD

M

C

C

2

PU

BL

S

L2

CONTACTOR

CONDENSER MOTOR

COMPRESSOR

EVAPORATOR MOTOR

EQUPIMENT GROUND

LOW VOLTAGE JUNCTION BOX

FEMALE PLUG / CONNECTOR

RUN CAPACITOR FOR

COMPRESSOR AND FAN

TERMINAL BLOCK (24V SIGNAL)

TRANSFORMER

TR

TR

BOX

LVJB

OF OVER CURRENT PROTECTION

PLF 2

BL

BK

5

++

YL

COMP

SEE UNIT RATING PLATE FOR TYPE AND SIZE

208-240V

C

208

208-240/1/60

R

2

0

8

-

2

4

0

BL

Y/Y2

2

/

GND

6

1

RD

TB1

SMOKE/FIRE DETECTOR

REPLACES JUMPER

PK

N

G

BK

TB1

TB1

5

1 2

N

RD

BL

4

3

EM

G

L

C

GR

SEE NOTE 2

BL

208-240/1/60 0140L02103-A

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND

TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)

USE COPPER CONDUCTOR ONLY.

2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE

WHITE AND YELLOW LEADS FROM "3" AND "4" TO

"4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE

HIGHER SPEED SETTING IS USED.

3. FOR 208 VOLT TRANSFORMER OPERATION MOVE

BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2

ON TRANSFORMER.

4. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE.

5. ECONOMIZER PLUG LOCATED IN RETURN AIR

COMPARTMENT. REMOVE MALE PLUG AND ATTACH

FEMALE PLUG TO ECONOMIZER ACCESSORY.

RD

2

240

YL

H

NOTE 3

R

24V

THERMOSTAT

4

W2

W1

Y

Y2

C

G

PLF

6

5

C

Y1

TB1

TB1

RD

BK

YL

BK

BK

WH

BL

LPS

YL/PK

LPS

2

1

EM

3

C

4

5

SEE NOTE #2

TB1

GR

OR

WH

BR

PU

YL

5

1

OR

OR

O

O

S2

S1

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

BL

RD

OR

Y1

Y/Y2

YL

W

Y/Y2

BL

G
R

OR

W

NO ECONOMIZER

G

OR

YL

RD

Y/Y2

Y1

PK

WH

W

R

RD

WH
GR

C

O

R

YL

O

GR

Y1

G

WH

WITH ECONOMIZER OPTION

C

GR

THERMOSTAT

FIELD WIRING

BL

C

O

2 STAGE COOLING

TB1

G
R

W

Y
C
O

TB1

TB1

Y

W

O

R

G

C

W

Y2

G
R

C
O

Y1

STAT

STAT

STAT

BL/PK BLUE WITH PINK STRIP

YL/PK YELLOW WITH PINK STRIP

GR GREEN

WIRE CODE

BL BLUE

PU PURPLE

PK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW

HPS

BL/PK

YL

WH

GR

RD

RD

T2

L2

HPS

H

F

WH

NOTE 3

NOTE 4

NOTE 5

NOTE 5

2