beautypg.com

Iring, Iagram, Warning – Goodman Mfg SS-CPC36-72 User Manual

Page 36: Roduct, Pecifications, Hree, Hase, Rive

background image

36

www.goodmanmfg.com

SS-CPC36-72

SS-CPC36-72

www.goodmanmfg.com

37

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

iring

d

iagram

CpC036-72*3B (t

hree

p

hase

, B

elt

d

rive

)

Wiring is subject t

o chang

e. Alw

ay

s

re

fer

to the wiring diagr

am or the

unit

for the mos

t up-t

o-da

te

wiring.

W

arning

High

Volt

ag

e:

Disc

onn

ect

all

po

w

er

be

for

e

ser

vicing

or

in

st

alling

this

unit.

Multiple

po

w

er

sour

ces

ma

y

be pr

esen

t. F

ailur

e

to do

so ma

y

cause pr

operty

damag

e,

per

sonal

injur

y,

or dea

th.

H

1

PU

2

GR

3

BR

Y1

T

BL

3 6

/

4

RD

YL

6

0

WH

PU

LVJB

PLF 2

5

GND

OR

PU

YL

YL

F

T

CONTROL

BR

T1

O

1

4

BR

BR

BK

9

RD

R

RCCF

3

C

W2

T

PLF 1

BL

7

5

PU

T3

G

T2

R

WH

A

GR

CM

W1

RD

8

E

YL

M

2

BL

S

BOX

++

YL

COMP

C

Y/Y2

6

LPS

HPS

BL/PK

YL/PK

TB1

PU

OR

O

RD
GR

BK

NOTE #2

GR

C

RD

SEE

NOTE #2

BK

BL

T1

T2

M2

3

YL

BK

EBTDR

BL

YL/PK

M1

K1

L1

BK

PU

RD

BR

1

K1

24V

L2

BR

C

GR

TR

NO

NC

BL

RD

BK

T3

208

L3

2

0

8

-

2

4

0

-

4

6

0

-

5

7

5

RD

BL

COM

/

RD

RD

BK

BK

RD

PK

TB1

SMOKE/FIRE DETECTOR

REPLACES JUMPER

S1

2

240

460

575

S2

RD

BL

G

XFMR-R

XFMR-C

BK

SPEED

C

UP

R

BL

RD

BL

OR

GR

T3

BK

BC

T1

RD OR

C

EM

T2

L1

L2

L3

SEE NOTE #3

C

RCCF

EBTDR

C

L2

R

4

T3

T1

5

Y

Y2

COMP

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND

TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)

USE COPPER CONDUCTOR ONLY.

2. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR

COMPARTMENT, REMOVE MALE PLUG, ATTACH

FEMALE PLUG TO THE ECONOMIZER ACCESSORY.

4. FOR 208 VOLT TRANSFORMER OPERATION MOVE

BLACK WIRES FROM TERMINAL 3 TO TERMINAL 2

ON TRANSFORMER.

T2

O

G

P

L

F

1

THERMOSTAT

3

6

F

208-240-460-575/3/60 0140L00427 REV. B

Y1

R

COMPONENT LEGEND

G

SUPPLY VOLTAGE

CM

W2

EM

L1

W1

C

T1

6

BC

C

CM

CMR

COMP

DC

DFT

ECON

EBTD

EMR

R

EM

FC

GND

HPS

HVDR

LPS

LVDR

LVJB

PB

PLF

RVC

RCCF

TB1

TR

3

C

1

C

C

24V

PLF2

C

T3

L3

BLOWER CONTACTOR

CONTACTOR

CONDENSER MOTOR

CONDENSER MOTOR RELAY

COMPRESSOR

DEFROST CONTROL

DEFROST THERMOSTAT

ECONOMIZER

ELECTRONIC BLOWER TIME DELAY

EVAPORATOR MOTOR RELAY

RELAY

EVAPORATOR MOTOR

FAN CAPACITOR

EQUPIMENT GROUND

HIGH PRESSURE SWITCH

HIGH VOLTAGE DEFROST RELAY

LOW PRESSURE SWITCH

LOW VOLTAGE DEFROST RELAY

LOW VOLTAGE JUNCTION BOX

POWER DISTRUBTION BLOCK

FEMALE PLUG / CONNECTOR

REVERSING VAVLE COIL

RUN CAPACITOR FOR

COMPRESSOR AND FAN

TERMINAL BLOCK (24V SIGNAL)

TRANSFORMER

TR

4

OF OVER CURRENT PROTECTION

5

BC

SEE UNIT RATING PLATE FOR TYPE AND SIZE

208-240V

208-240/3/60

T2

P

L

F

1

2

1

BC

EBTDR

R

EBTDR

HPS

LPS

BC

TB1

TB1

BC

++

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

BL

RD

OR

Y1

Y/Y2

YL

W

Y/Y2

BL

G
R

OR

W

NO ECONOMIZER

G

OR

YL

RD

Y/Y2

Y1

PK

WH

W

R

RD

WH
GR

C

O

R

YL

O

GR

Y1

G

WH

WITH ECONOMIZER OPTION

C

GR

THERMOSTAT

FIELD WIRING

BL

C

O

2 STAGE COOLING

TB1

G
R

W

Y
C

O

TB1

TB1

Y

W

O

R

G

C

W

Y2

G
R

C

O

Y1

STAT

STAT

STAT

BL/PK BLUE WITH PINK STRIP

YL/PK YELLOW WITH PINK STRIP

GR GREEN

WIRE CODE

BL BLUE

PU PURPLE

PK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW