Wiring diagrams, Iring, Iagram – Goodman Mfg SS-CPC36-72 User Manual

Page 34: Warning, Roduct, Pecifications, Ingle, Hase, Irect, Rive

background image

34

www.goodmanmfg.com

SS-CPC36-72

SS-CPC36-72

www.goodmanmfg.com

35

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

iring

d

iagram

CpC036/48*1d (s

ingle

p

hase

, d

ireCt

d

rive

)

H

1

RCCF

T

PU

CONTROL

BR

C

2

T1

S

T1

GR

BK

O

1

YL

4

BR

1

BR

T1

BK

9

RD

COMP

R

BR

RCCF

T2

3

C

W2

T

Y1

PLF 1

3

T

YL/PK

PU

F

BL

3 6

7

5

PU

T3

G

T2

COMPONENT LEGEND

BL

L1

SUPPLY VOLTAGE

CM

BK

R

EM

/

L1

4

C

RD

YL

6

0

BC

BIR

C

CM

COMP

EM

GND

HPS

LPS

PLF

RCCF

TB1

TR

WH

C

A

GR

CM

W1

YL

8

E

RD

M

C

C

2

PU

S

L2

BLOWER CAPACITOR

BLOWER INTERLOCK RELAY

CONTACTOR

CONDENSER MOTOR

COMPRESSOR

EVAPORATOR MOTOR

EQUPIMENT GROUND

HIGH PRESSURE SWITCH

LOW PRESSURE SWITCH

FEMALE PLUG / CONNECTOR

RUN CAPACITOR FOR

CONDENSER FAN

TERMINAL BLOCK (24V SIGNAL)

TRANSFORMER

TR

BOX

OF OVER CURRENT PROTECTION

PLF 2

BL

BK

5

++

YL

COMP

SEE UNIT RATING PLATE FOR TYPE AND SIZE

208-240V

O

208-240/1/60

R

2

0

8

-

2

4

0

BK

Y/Y2

/

GND

6

1

PB

TB1

BL

BL

208-240/1/60 0140L00504 REV A

SEE NOTE 3

24V

RD

RD

T2

L2

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND

TYPE INSULATION AS ORIGINAL (AT LEAST

105°C) USE COPPER CONDUCTOR ONLY.

2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE

M1 OR M2 WIRE TO COM TERMINAL ON EBTDR

AND PLACE WIRE REVMOVED FROM COM ON

EMPTY M1 OR M2 TERMINAL.

3. FOR 208 VOLT TRANSFORMER OPERATION

MOVE BLACK WIRES FROM TERMINAL

3 TO TERMINAL 2 ON TRANSFORMER.

4. USE COPPER CONDUCTORS ONLY ++ USE N.E.C.

CLASS 2 WIRE

5. ECONOMIZER PLUG LOCATED IN THE RETURN

AIR COMPARTMENT. REMOVE MALE PLUG AND

ATTACH FEMALE PLUG TO ECONOMIZER

ACCESSORY.

6. DIAGRAM SHOWS FACTORY SPEED TAP SETTINGS.

WH

GR

TB1

F

LPS

YL/PK

YL

BL

RD

OR

Y1

Y/Y2

YL

W

Y/Y2

BL

G

R

OR

W

NO ECONOMIZER

G

OR

YL

RD

Y/Y2

Y1

PK

WH

W

R

RD

WH
GR

C

O

R

YL

O

GR

Y1

G

WH

WITH ECONOMIZER OPTION

C

GR

THERMOSTAT

FIELD WIRING

BL

C

O

2 STAGE COOLING

TB1

G
R

W

Y2

C
O

TB1

TB1

Y

W

O

R

G

C

W

Y2

G
R

C

O

Y1

STAT

STAT

STAT

C

BL/PK

HPS

BL

PU

BR

C

RD

2

3

K1

RD

BK

BK

BC

BK

24V

COM

TR

UP

BL

M2

BK

240

GR

NC

SPEED

EBTDR

PU

R

XFMR-R

XFMR-C

BL

G

K1

M1

EM

NO

1

SEE

NOTE #2

RD

PU

BL

C

3 SPEED

BR

BL

BK

208

SMOKE/FIRE DETECTOR

REPLACES JUMPER

TB1

S2

S1

PK

RD

BK

RD

BR

BL

BIR

BK

BR

EBTDR

BR

8
9

7

R

O

HPS

C

LPS

SEE NOTE 5

Y/

Y2

TB1

5
6

PLF

G

C

Y1

W1

4

THERMOSTAT

W2

2

PLF2

1

3

6 5 4

R

R

C

G

EBTDR

XFMR

PU

ALTERNATE

MOTOR

6-WIRES

SEE TABLE 1

BC

3 SPEED

BL

EM

RD

BK

BR

RD

PU

TABLE 1

ALTERNATE MOTOR WIRING

TABLE 2

SPEED TAPS

COLOR

RD

BK

BL

PU

TERMINATION

COM (EBTDR)

M1 (EBTDR)

M2 (EBTDR)

PIN 1 (24V XFMR)

RD

BL

BK

LOW

MED

HIGH

H

BL

OR

BK

BK

PU

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

GR GREEN

WIRE CODE

BL BLUE

PU PURPLE

PK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP

YL

1

3

2

OR

RD

H

Wiring is subject t

o chang

e. Alw

ay

s

re

fer

to the wiring diagr

am or the

unit

for the mos

t up-t

o-da

te

wiring.

W

arning

High

Volt

ag

e:

Disc

onn

ect

all

po

w

er

be

for

e

ser

vicing

or

in

st

alling

this

unit.

Multiple

po

w

er

sour

ces

ma

y

be pr

esen

t. F

ailur

e

to do

so ma

y

cause pr

operty

damag

e,

per

sonal

injur

y,

or dea

th.