Choke replacement, Varistor replacement – Graco ULTRA AIRLESS 230-963 User Manual
Page 22
CHOKE REPLACEMENT (See Fig
1. Remove the pressure control cover and screws.
2. Remove the grounding screw
and remove the
lead. Loosen the appropriate screw on the terminal
lead.
strip (336) and
the
choke
3.
Use
the M8 wrench
to
remove the upper nut and
lockwasher
on the outside of the
pressure control box.
4.
Remove the old choke
and install a new one in
the reverse order of disassembly.
Fig
17
VARISTOR
REPLACEMENT (See Figs 18
WARNING
Relief Procedure Warning on page 17 to reduce
the risk of a fluid injection injury, splashing in the
eyes or on the skin, injury from moving parts, or
1.
2.
3.
4.
5.
Remove the control box screws and cover.
Remove the
two
screws
the wiring
harnesses
and the old varistor from the
ONlOFF switch
Trim the leads on the new varistor
to 28.5
in.). Turn each lead outward to form a loop
that
is
large enough for the screws
to pass
through.
loop of the varistor leads on each screw and thread
Place a wiring harness on each screw, then place a
the screws into the switch.
Wrap the varistor under the switch.
307-671
21