beautypg.com

Graco ULTRA AIRLESS 230-963 User Manual

Page 13

background image

TYPE OF

PROBLEM

LOW OUTPUT

NO OUTPUT

Motor runs and pump stroke:

WHAT TO CHECK

If

check is

OK.

go t o next check

1. Check for worn spray tip.

2. Check

to see

that

pump does not con-

tinue

to

stroke when gun trigger is

released. Plug in and turn on sprayer.

Prime with paint. Trigger gun momen-

tarily, then release and engage safety

latch. Relieve pressure, turn

off and

unplug sprayer.

3. Check electrical supply with volt meter.

Meter should read

Volts.

4. Check extension cord size and length;

must be at least 12 gauge wire and no

longer than 15.2 m

5. Check

and

leads from bridge

or loose wires or connectors. Refer

to

to

circuit board

for damage

page

22.

6.

Check stall pressure. Refer

to Calibration

Procedure on page 24.

7.

Check bridge

+

and

-

leads and

terminals

to motor. Inspect

wiring

in-

sulation and terminals for signs of

overheating. See page

20.

8. Check for loose motor brush leads and

terminals. See page

27.

9. Check for worn motor brushes which

should be 14 mm

minimum. See

for broken and misaligned motor

brush springs. Rolled portion of spring

must rest squarely on top of brush.

motor brushes for binding

in

brush holders. See page 27.

circuit board

by substituting

with a good circuit board. See page

22.

motor armature for

by us-

ing an armature tester (growler) or per-

form spin

test.

See

page 15.

bridge

by substituting with

a good bridge or by performing the

bridge test. See page 16 or

20.

CAUTION:

Do

not perform this check

A bad armature

will immediately burn

until armature is determined

to be good.

out

a good bridge.

1.

Check paint supply.

2. Check for clogged intake strainer.
3. Check for loose suction tube or fittings.

WHAT

TO

DO

If

check

is

NOT

OK refer to this column

1. Follow Pressure Relief Procedure

Warning then replace

tip.

See your

separate gun or tip manual.

2. Service pump. See manual

3. Reset building circuit breaker; replace

building fuse. Repair electrical outlet or

try

another outlet.

4. Replace with a correct, grounded exten-

sion cord.

5. Clean circuit board male terminals.

minals. Securely reconnect lead

Replace loose or defective lead ter-

minals to board.

6. Calibrate pressure control. See page 24.

7. Be sure male terminal

are

centered and firmly connected to female

terminals. Replace any loose terminal or

damaged wiring. Securely reconnect

wires to bridge.

8.

Tighten terminal screws. Replace

brushes if leads are damaged. See page

27.

9. Replace brushes. See page

27.

spring if broken. Realign spring

with brush. See page

27.

11 .Clean brush holders, remove carbon

dust with small cleaning brush. Align

brush lead with

slot in brush holder to

free vertical brush movement.

circuit board. See page

22.

motor.

See page

bridge. See page

1. Refill and

pump.

2.

Remove and clean, then reinstall.

3. Tighten; use thread sealant or sealing

tape on threads if