SWITCH REPLACEMENT

(See Figs 14

WARNING

Before doing this procedure, follow the Pressure

Relief Procedure Warning on page 17 to reduce

the risk of a fluid injection injury, splashing

in

the

eyes or on the skin, injury from moving parts, or

electric

shock.

Remove the pressure control cover and screws.

2. Remove the wires attached to the switch

at

and

using a screwdriver. See page

Fig

21.

3.

Use a 16 mm socket wrench to loosen and remove

the nut and rubber boot

from the top of the

pressure control box. Remove the switch guard

4. Remove the

switch.

5. Remove the wires attached to the switch TP4 and

TP3 using a screwdriver. See page

Fig 21.

6. Attach the wires to TP4 and TP3 of the new switch.
7. Install the new switch so the internal tab of the

rotation ring

engages with the vertical groove

engages with the blind hole

of the pressure

in

the threads of the switch, and the external tab

trol box.

8. Install the switch guard

aligning the internal

tab with the groove in the threads.

9. Powder the inside of the rubber boot

with

talcum, then shake excess out of boot.

10. Install the nut and rubber boot and tighten.
11. Reconnect the wires to

and

12. Reinstall the pressure control cover and screws.

REPLACEMENT

(See Fig 15)

Before doing this procedure, follow the Pressure

the risk of a fluid injection injury, splashing

in

the

Relief Procedure Warning on page 17 to reduce

eyes or on the skin, injury from moving parts, or

1. Remove the pressure control cover and screws.

2. Disconnect both wires from the microswitch
3. Use the socket wrench to remove the nuts from the

microswitch.

4. Check to see if the flag

is loose. If

it

is, be sure

the fluid pressure is

0

bar psi), then loosen the

two

6

mm hex nuts behind the microswitch. Adjust

the distance from the top of the flat to top inside

of

the pressure control box to

mm

in.).

Tighten the screwsand recheck

the dimension. Refer to Fig 1.

5. Perform the

STALL PRESSURE CALIBRATION

on page 24 before regular operation of the sprayer.

6. Reinstall the cover

and screws.

15)

Fig

14

Fig

15