beautypg.com

Drive housing, Warning – Graco TEXSPRAY 1030 User Manual

Page 15

background image

309662

15

Drive Housing

TI3023A

Torque to
25 ft--lb
(34 N.m)

Fig. 9

1

19

39

8

8g

8h

91

36

58

40

150a

64

1

A

Apply remaining
grease to these
areas

2

2

59

84

92

84

36

93

56

21

To reduce risk of injury due to sprayer starting

unexpectedly, shut off engine before performing

checks or service.

WARNING

1. Fig. 9. Disconnect siphon hose elbow (150a), drain

hose (64) and material hose (not shown) from

pump outlet. Disconnect cables. Remove screws

(21) and front cover (19).

2. Remove four screws (40) and lockwashers (56)

from bearing housing (39).

3. Lightly tap back of bearing housing (39) with a

plastic mallet. Pull pump, bearing housing and

connecting rod away from drive housing (8) as one

assembly.

4. Remove bearing housing screws (93) and lock-

washer (36) and pinion housing screws (59) and

lockwashers (36).

5. Lightly tap around drive housing (8) to loosen drive

housing. Pull drive housing straight off pinion

housing (58). Be prepared to support combination

gear (91), which may also come out.

6. Liberally apply bearing grease (supplied with

combination gear) to combination gear (91) and to

areas called out by note 2.

7. Place bronze colored washer (8g) and then silver-

colored washer (8g) on shaft protruding from big

bearing of drive housing (8). Align gears and push

new drive housing straight onto pinion housing and

locating pins (A).