B1.0

SPECIFICATIONS - FOR DUAL-SPEED DS8016 HUBS

Power Supply (Internal 48 VDC Option)

DC Power Connector: 3 terminals: “

-

“, “GND”, “+”

Input Voltage: 36 - 70 VDC (auto-ranging)

Power Consumption: Model DS8016: 25 watt typical, 40 watts max.

With the exception of the power supply, all specifications and functions of

Magnum DS80016-48VDC models are identical to those listed in Section 1.

B2.0

48V DC SOURCE OPTION, THEORY OF OPERATION

The 48VDC power option is designed using diodes inside on each DC power input

line behind the two external power connection terminals, so that the power from an external

source can only flow into the hub. This

allows the hub to operate only whenever

DC power is correctly applied to the two

inputs. It protects the hub from incorrect

DC input connections. An incorrect

polarity connection, for example, will neither effect the hub, nor its power supply internally,

nor will it blow the fuse in the internal power supply.

A+

A-

GND

GND

CHASSIS

FUSE

+

-

SUPPLY

HUB

POWER SWITCH

The power switch (included on premium-priced NEBS-certified units only) is used

for powering the hub on and off when it is placed into or taken out of service.

B3.0

APPLICATIONS

Magnum DS8016 Dual-Speed Hubs are easily installed in a variety of applications

where 48 VDC power is used as the primary power source. The 48VDC power configuration

provides an Ethernet networking solution utilizing a special power supply in hubs with a

proven track record.

The solution is particularly useful in the telecommunication industry, where it is

common for facilities to operate on 48VDC power. Such companies include regular and

wireless telephone service providers, Internet Service Providers (ISPs) and other

communication companies. In addition, many high availability equipment services, such as

broadcasters, publishers, newspaper operations, brokerage firms and other facilities often use

a battery backup system to maintain operations in the event of a power failure. It is also

frequently used for computer system backup, management and operations monitoring

equipment.