4 up-link port 1x, 3 led’s, Up-link port 1x – GarrettCom DS8016 User Manual
Page 34
Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06)
26
www GarrettCom com
.
.
4.3 LED’s
PWR
: Illuminates GREEN to indicate AC power is applied to the unit.
COL
: Red LED Blinks intermittently when a collision occurs.
BR : Bridge Module Indicator, On when 10/100 bridge module is
installed (Model DS8016-B), Off when no bridge module is inside
(DS8016A)
100/Auto : Speed LED per port. Steady On when speed is 100Mbps , Off when
speed is 10Mb, flashing when auto-negotiating or when not
connected (no LINK)
LK/RX : Activity LED per port. Steady On when twisted-pair link is
operational. Activity, flashing when port is receiving data.
4.4
Up-link Port 1X
Magnum DS8016s each have one Up-link port, port # 1X, which can be used
when port #1 is not connected. The Up-link port allows repeater-to-repeater connections
without a special cross-over cable. It works the same for 10Mb or 100Mb connections.
Use port “1” (or ports 2 thru 16) for straight-through twisted pair cabling from
the DS8016 port to a user device, or the “1X” port for cross-over or up-link segment
connections from the first DS8016 port to a repeater or hub or switch. Verify proper port
connection by noting the port’s LINK/RX status, which is illuminated when a proper link
is made and blinking when there is activity.
Note: Port # 1 and Port # 1X, provided for RJ45 connections, are logically one port.
Only one of these ports, either # 1 or # 1X may be used at one time simultaneously.