Magnum DS8016 Dual-Speed Stackable Hubs Installation and User Guide (07/06)

20

www GarrettCom com

.

.

where 111 is the BT delay for

100m of Category 5 cable (1.112

BT/m* 100m), 80 is the BT delay

for each Magnum DS8016 , 100 is

the BT delay for the TX DTE pair,

and a safety margin of 2 was used.

Figu

re 3.2.3a: Two cascaded Magnum DS8016 hubs

100 m Cat. 5 cables

to user devices

100 m Cat. 5 cables

to user devices

Cat. 5 cable for

cascading

100

COL 10
COL 100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

X

LK/RX

PORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

PWR

BR

Bl ack Box Rackmount Dual Speed Hub

100

COL 10
COL 100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

X

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

LK/RX
POR T

PWR

BR

Black Box Rackmount Dual Speed Hub

The resulting value tells us that a Category 5 cable with a length of up to 25 meters

may be used to cascade the Magnum DS8016 s. Note that this inter-repeater cable length

may be increased by shortening the lengths of the 100m hub-to-user cable segments.

It is also possible to cascade a group of up to nine Magnum DS8016 s (serving up

to 56 users with full-length 100m cables to each) by using short inter-repeater cable

segments. The following is an example of how to calculate the maximum allowable cascade

cable segment length. An illustration of this example is shown in Figure 3.2.3b, where the

hub-to-user cable lengths are up to 75 meters for Cat 5 twisted pair. The variable “X”, the

maximum hub-to-hub cable delay, is calculated as follows:

PDV = X + ((100) + (80 + 80 + 80 )+ (83 + 83) + 2 ) BT < 512 BT
512 > (X + 508) BT, X < 4 BT
Twisted pair user cable length, TL < (4 BT) / (1.112 m/BT)
TL < 3.6 meters for two hub-to-hub cascading cables

2

meters (6 ft.) length max. for each of the cascade segments,

In the above example, 75 is the BT delay for 70m of Category 5 cable (1.112 BT/m), 80 is

the bit time delay for each Magnum DS8016 front-to-front ports, 100 is the BT delay for the

TX DTE pair in the user stations, and 2 BT is the safety margin applied.

100 m

to us

Cat. 5 cables

er devices

100 m Cat. 5 cables

to user devices

Cat. 5 cable for

cascading

100

COL 10
COL 100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

X

LK/RX

PORT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

PWR

BR

Bl ack Box Rackmount Dual Speed Hub

100

COL 10
COL 100

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

X

13 14 15 16

LK/RX

POR T 1 2 3 4 5 6 7 8 9 10 11 12

PWR

BR

Bl ack Box Rackmount Dual Speed Hub

Figure 3.2.3b: Multiple

cascaded Magnum

DS8016 hubs

Note that the

cascading of multiple

Magnum DS8016 hubs is a

capability beyond what