beautypg.com

Installation, Warning, Fluid line accessories – Graco Inc. UNICARB Pro AA4500 User Manual

Page 7

background image

308936 7

Installation

01945B

Fig. 1

KEY

A* Bleed-type Air Shutoff Valve
B

Air Line Filter

H

Fluid Shutoff Valve

K

Pressure Gauge

L* Grounded Braid Type Fluid Hose

with spring guards

M

Gun Fluid Inlet (1/4 npsm)

N

Gun Air Regulator

P

Gun Air Shut-off Valve

Q* Graco Electrically Conductive

Air Supply Hose
(1/4 npsm x 1/4 npsm LH)

R* Fluid Drain Valve
S

Fluid Filter

W PRO AA4500/UNICARB Spray Gun
X

Gun Air Inlet (1/4 npsm LH)

Y

Shrouded/Vented Waste Container

*

Equipment required for safe operation of
system. Must be purchased separately.
See
ACCESSORIES.

A

B

H

K

S

R

L

N

P

Q

M

R

WARNING

SIGN

W

X

Y

Fluid Line Accessories

(Refer to Fig. 1)

1.

Install a fluid filter (S) and drain valve (R) at the
pump outlet. Filtering the fluid will help remove
coarse particles and sediment that could clog the
spray tip.

WARNING

INJECTION HAZARD
The fluid drain valve (R) is required in
your system to assist in relieving fluid
pressure in the supply system, hose and

gun; triggering the gun to relieve pressure may not
be sufficient. Install a drain valve close to the
pump’s fluid outlet. The drain valve reduces the risk
of serious injury, including fluid injection and
splashing in the eyes or on the skin.

2.

Install a fluid regulator (J) on the fluid line to con-
trol fluid pressure to the gun.

This manual is related to the following products: