beautypg.com

Environmental specifications – Gateway 820 LTO User Manual

Page 62

background image

58

Chapter A:

www.gateway.com

Environmental specifications

(1) All operating specifications include a data cartridge. These measurements

assume that the autoloader is installed in accordance with the installation
instructions.

(2) The autoloader is in its original packaging.

(3) The autoloader has been unpacked but is still in its protective antistatic bag.

The packaging is designed to protect the autoloader from the condensation
caused by extreme temperature variations (15° C or more). When the auto-
loader is moved from a cold storage environment to a warm operating envi-
ronment, it must acclimate in its packaging for at least 12 hours before
opening to prevent serious condensation damage from occurring.

(4) The autoloader has not been unpacked. The transportation period does not

exceed 72 hours.

(5) The data cartridges must be allowed to stabilize in the specified ambient tem-

perature and humidity for 24 hours before use.

Specification

Operating (1)

Storage (2) or
non-operating (3)

Transportation (4)

Ambient
temperature range

+50° F to +104° F
(+10° C to +40° C)

-40° F to +140° F
(-40° C to +60° C)

-4° F to +140° F
(-20° C to +60° C)

Temperature
variation (5)
(thermal gradient)

2° F per minute;
max 18° F per hour
(1° C per minute;
max 10° C per hour)

1° F per minute; max
36° F per hour
(1° C per minute;
max 20° C per hour)

2° F per minute; max
36° F per hour
(1° C per minute; max
20°C per hour)

Relative humidity
(humidity gradient)

20% to 80%;
Non-condensing
10% per hour

10% to 80%;
Non-condensing
10% per hour

10% to 80%;
Non-condensing 10%
per hour

Wet bulb

79° F (26° C) max

84° F (29° C) max

84° F (29° C) max

Altitude

-1000 ft. to
+30,000 ft.
(-304.8 m to
+9,144 m)

-1000 ft. to
+30,000 ft.
(-304.8 m to
+9,144 m)

-1000 ft. to +30,000 ft.
(-304.8 m to +9,144 m)