Technical specification, These instructions cover the following models – Stovax 8455 User Manual
Page 9
9
TECHNICAL SPECIFICATION
THESE INSTRUCTIONS COVER THE FOLLOWING MODELS:
VFC RADIANT
VFC CONVECTOR
VFC LOW CONVECTOR
8300UC
16”
8420UC
16”
8461UC 16”LL
P8300UC 16”
P8420UC 16”
P8461UC 16”LL
8301UC
16”RD
8421UC
16”RD
8463UC
16”RD LL
P8301UC 16”RD
P8421UC 16”RD
P8463UC 16”RD LL
8305UC
18”
8425UC 18”
8466UC 18”LL
P8305UC 18”
P8425UC 18”
P8466UC 18”LL
8310UC
22”
8430UC
22”
8471UC 22”LL
P8310UC 22”
P8430UC 22”
P8471UC 22”LL
Model
Gas
CAT
Gas
Type
Working
Pressure
Aeration
Injector
Gas Rate
m3⁄h
Input kW (Gross)
Max
Flue
Temp
Country
High
Low
16 RD
I
2H
Natural Gas (G20)
20 mbar
12N
400
.653
6.85
3.0
160°C
GB, IE
I
3+
Butane (G30)
29 mbar
RDL
180
.190
6.65
2.8
Propane (G31)
37mbar
.250
16
I
2H
Natural Gas (G20)
20 mbar
12N
600
.900
9.45
3.7
190°C
GB, IE
I
3+
Butane (G30)
29 mbar
9L
260
.272
9.50
4.2
Propane (G31)
37mbar
.358
18
I
2H
Natural Gas (G20)
20mbar
11N
700
1.010
10.60
3.8
200°C
GB, IE
I
3+
Butane (G30)
29 mbar
9L
300
.303
10.60
5.0
Propane (G31)
37mbar
.399
22
I
2H
Natural Gas (G20)
20 mbar
9N
850
1.172
12.30
5.2
210°C
GB, IE
Butane (G30)
29 mbar
0L
360
.363
12.70
5.35
Propane (G31)
37mbar
.478
Efficiency Class II
Flue Outlet Size 178 mm (7”) ø
Gas Inlet Connection Size 8 mm ø
Minimum flue specification T260/N2/O/D/1