This appliance must be serviced at least one a year by a

competent person.

1. SERVICING REQUIREMENTS

1.1 As part of the annual service, the space behind the convector

must be inspected for any debris, which may have fallen down

the chimney.

1.2 Remove the gas fire from the convector as detailed in section 4

1.3 Remove the convector box from the wall, see section 5 in

Installation.

1.3 Inspect the space behind the convector for debris and the

condition of the chimney, the flue flow test should be carried

out now. Remove any debris and carry out any necessary

remedial work.

2. FAULT FINDING

This is for use only by qualified Installers and Service Engineers.

Note: Many problems can be attributed to poor pilot flame length

caused by blocked jets as the orifice is very small. If the flame

length is much shorter than that shown in the Diagram, the pilot

may have to be changed. See Diagram 7.

It is always worth using the nozzle of a vacuum cleaner over the

end of the pilot to ensure that it has no debris within it. In

addition, many ignition problems are caused by incorrect spark

gap, ensure it is set as in Diagram 7.

7

AR0097

SERVICING INSTRUCTIONS

SERVICING REQUIREMENTS

FLAME FAILURE FUNCTIONAL CHECK

PILOT WILL NOT STAY LIT OR FIRE GOES OUT

If the appliance goes out in use continually, this may mean

that the

oxygen depletion sensor has been activated. The appliance

should not be used

until the cause has been found and rectified.

Ensure there is no debris around the pilot assembly, e.g.

coal, soot, etc.

Check for fluff in the pilot aeration hole. See Diagram 7.

Light the pilot and keep the control knob pushed in at least

10 seconds before letting go

With the pilot

running is the

gas pressure

as

stated on the

databadge?

Is the pilot

flame of the

correct

length?

See Diagram

7.

Is

thermocouple

connection

good

in back of

valve

Replace

ODS unit

Change the

ODS unit

SYSTEM O.K

Tighten the

connection

and retry

With the fire

running on

full is

the gas at the

pressure

stated

on the

databadge

Problem is

with

the pipework

or

fittings which

lead to the

fire. Correct

and retry

Run for 60

sec’s.,

turn off, time

interval until

mag unit

shuts with a

click. Is this

greater

than 7

seconds?

Run for 60

sec’s.,

turn off, time

interval until

mag unit

shuts with a

click. Is this

greater

than 7

seconds?

Will the pilot

stay lit?

Will the pilot

stay lit?

Change

mag unit

YES

NO

NO

NO

NO

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES