beautypg.com

Fault finding – Stovax 8455 User Manual

Page 20

background image

20

FAULT FINDING

IGNITION

FUNCTIONAL

CHECK

1

PILOT

WILL

NOT

LIGHT

Ensure

there

is

no

debris

around

the

pilot

assembly,

e.g

coal,

soot,

etc

which

could

short

the

spark,

clean

the

area.

Check

for

fluff

in

the

pilot

aeration

hole.

See

Diagram

7,

arrow

A.

There

is

a

blockage

in

the

system,

check

the

inlet

test

point,

the

mag

seating,

valve

and

pilot

filter.

Operate

the

valve.

Is

there

a

spark?

Consult

users

book

and

retry

Ensure

gap

between

the

electrode

&

thermocouple

is

as

Dia.

7

&

retry.

If

gap

is

OK

then

first

change

the

ignition

lead

&

retry,

if

still

no

good

then

change

gas

valve

Is

the

control

being

operated

correctly?

Will

the

pilot

light

with

a

match

Is

the

gas

turned

on

to

the

appliance?

Check

isolation

tap

and

gas

meter,

retry

Purge

the

gas

pipes

and

retry

See

“NO

SPARK”

chart*

System

OK

Is

the

gas

pressure

correct?

Has

the

system

got

any

air

in

it?

Does

the

pilot

light?

Correct

and

retry

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

NO

NO

YES

YES

IGNITION

FUNCTIONAL

CHECK

2

NO

SPARK

Ensure

there

is

no

debris

around

the

pilot

assembly,

e.g

coal,

soot,

etc

which

could

short

the

spark,

clean

the

area.

Consult

users

instructions,

retry

Operate

the

valve.

Light

the

pilot,

does

the

valve

click?

Is

the

gap

between

the

electrode

&

thermocouple

as

in

Dia.

7?

Is

the

control

being

operated

correctly?

Reset

the

pilot

burner

Correct

and

retry

Has

ignition

lead

become

detached

or

is

connection

poor?

Replace

the

ODS

unit

Replace

the

electrode

lead

and

retry

Replace

the

gas

valve

and

retry

Check

for

defective

or

damaged

control

knob

spindle

or

cam

operation.

Check

for

correct

location

of

piezo

components.

Correct

and

retry

Remove

the

electrode

lead

from

the

piezo.

Operate

the

valve.

Does

a

spark

jump

from

the

piezo

to

the

valve

body?

Remove

the

electrode

lead

from

electrode

with

insulated

pliers

hold

the

tip

3.5mm

from

the

pilot

pipework,

is

there

a

spark

when

the

valve

‘clicks’?

Is

the

electrode

wire

detached

from

the

piezo

in

the

valve?

Replace

the

gas

valve,

retry

YES

YES

NO

NO

*

NO

NO

YES

YES

YES