User instructions, ’running in, Servicing – Stovax 8455 User Manual
Page 8: Ventilation, Installation details, Oxygen depletion sensor, The flame failure device
8
10.’RUNNING IN’
The surface coating on the coals used in your GAZCO fire will
‘burn off’ during the first few hours of use, producing a
harmless and temporary odour. This will disappear after a
short period of use. If the odour persists, ask your installer for
advice.
11. SERVICING
This fire must be serviced every 12 months by a qualified Gas
Engineer. In all correspondence, always quote the appliance
type and serial number, which may be found on the
databadge, adjacent to the control knob.
12. VENTILATION
Any purpose provided ventilation should be checked
periodically to ensure that it is free from obstruction.
13. INSTALLATION DETAILS
To assist in any future correspondence, your retailer should
have completed this commissioning sheet, this records, the
essential installation details of the appliance. In all
correspondence always quote the model No and serial No.
USER INSTRUCTIONS
16
AR1128
7.17 Place the remaining 6 small coals on top of the others so
that they form a bridge between the second and third rows.
See Diagram 17.
17
AR1129
8. OXYGEN DEPLETION SENSOR
The appliance is fitted with an oxygen sensitive pilot system
which will act to cut off the gas supply to the fire should the
oxygen in the room fall below its normal level. If the fire is
turned off by this device, it usually indicates that there is a
problem with the flue system, and this should be inspected by
a qualified engineer.
Do not attempt to use the fire until an engineer says it is
safe to do so.
This device is not a substitute for an independently
mounted carbon monoxide detector.
9. THE FLAME FAILURE DEVICE
This is a safety feature incorporated in all GAZCO fires which
automatically switches off the gas supply if the pilot light goes
out and fails to heat the thermocouple.