10.’RUNNING IN’

The surface coating on the coals used in your GAZCO fire will

‘burn off’ during the first few hours of use, producing a

harmless and temporary odour. This will disappear after a

short period of use. If the odour persists, ask your installer for

advice.

11. SERVICING

This fire must be serviced every 12 months by a qualified Gas

Engineer. In all correspondence, always quote the appliance

type and serial number, which may be found on the

databadge, adjacent to the control knob.

12. VENTILATION

Any purpose provided ventilation should be checked

periodically to ensure that it is free from obstruction.

13. INSTALLATION DETAILS

To assist in any future correspondence, your retailer should

have completed this commissioning sheet, this records, the

essential installation details of the appliance. In all

correspondence always quote the model No and serial No.

USER INSTRUCTIONS

16

AR1128

7.17 Place the remaining 6 small coals on top of the others so

that they form a bridge between the second and third rows.

See Diagram 17.

17

AR1129

8. OXYGEN DEPLETION SENSOR

The appliance is fitted with an oxygen sensitive pilot system

which will act to cut off the gas supply to the fire should the

oxygen in the room fall below its normal level. If the fire is

turned off by this device, it usually indicates that there is a

problem with the flue system, and this should be inspected by

a qualified engineer.

Do not attempt to use the fire until an engineer says it is

safe to do so.

This device is not a substitute for an independently

mounted carbon monoxide detector.

9. THE FLAME FAILURE DEVICE

This is a safety feature incorporated in all GAZCO fires which

automatically switches off the gas supply if the pilot light goes

out and fails to heat the thermocouple.