4.6 Check the gas connections to the fire are sound. Light the fire

and check all joints on the appliance.

4.7 Check the appliance running pressure is correct. See

databadge.

4.8 Fit the fret to the fire front using two screws. See Diagram 4.

4

AR0311

5. INSTALLATION - CONVECTOR FIRES

5.1 Make any necessary alterations to fireplace opening. Ensure

that the lintel does not obstruct the flue outlet into the flue,

and that there is a clear space for debris of at least 90mm. See

Diagram 5.

5

AR0300

5.2 Gas pipe entry must be through one of the holes in the rear

of the convector box. See Diagram 6 & 7.

6

AR0200

Note: Gas pipes passing through masonry must be

protected.

5.3 If the isolation tap is to be fitted under the fire, the GAZCO

GC0060 provides a neat and easy solution. See Diagram 7A.

7

7A

AR0306/7

5.4 Remove the fire assembly (see Diagram 9), and offer the

convector box into the opening, checking that it fits squarely.

Mark the fixing holes and the gas pipe entry positions. See

Diagram 8.

8

AR0313

5.5 Fit the gas pipe into position, ready for passing into the

convector box, ensuring enough remains to connect to the

fire.

INSTALLATION INSTRUCTIONS

INSTALLATION