Page 4.1-2

J1 PIN

WIRE

CIRCUIT FUNCTION

1

4

Field boost current to rotor (about 9-10 volts DC).

2

86

Low oil pressure shutdown. Automatic shutdown occurs when Wire 85 is grounded by loss of oil
pressure to the LOP.

3

23

Switched to ground for Transfer Relay (TR) operation.

4

194

12 VDC output from the circuit board for transfer relay, present in AUTO or MANUAL operation.

5

56

Energized (12 volts DC) by circuit board’s crank relay (K1) to crank the engine.

6

18

Engine shutdown. Circuit is grounded by circuit board action to ground the engine

7

14

12 VDC output for engine run condition. Used for fuel solenoid (FS), battery charge relay (BCR),
and hourmeter if equipped.

8

66A

AC input to the board for crank terminate and overspeed protection.

9

239

B+ input when SW1 is in the MANUAL position.

10

15A

B+ input into the board for source voltage when SW1 is in the AUTO or MANUAL position.

11

17

B+ output to SW1 for manual start operation.

12

15

12VDC source voltage for the circuit board. Also runs timer for exerciser.

13

0

Common ground.

14

225

Transformer reduced "Utility" source sensing voltage.

15

224

Transformer reduced "Utility" source sensing voltage.

16

NOT USED

17

NOT USED

J2 PIN

WIRE

CIRCUIT FUNCTION

1

NOT USED

2

85

High temperature oil engine safety.

3

351

Input set exercise. Signal to ground to set.

4

15B

Output for remote alarm relay, optional.

5

229

Output for remote alarm relay, optional.

Figure 3. Circuit Board