Disconnect mode, Force telnet mode – GE GFK-1852 User Manual
Page 36

4-14
VersaMax Serial to Ethernet Adapter User's Manual – July 2000
GFK-1852
4
ATD0.0.0.0
If a remote IP address and port number are defined within the
VMSE, this command
will force the VMSE into “monitor mode”.
ATDx.x.x.x
Without a port number, this will make a connection to the given IP address (x.x.x.x)
and the remote port number configured within the VMSE.
All other 'AT' commands with “connect mode” set to 0x16 will acknowledge
with an
OK, but will not be acted upon.
If the VMSE is in modem emulation mode and the serial port is idle, the VMSE can
still accept network TCP connections to the serial ports if the “connect mode” is set
to 0xC6 (with no echo) or 0xD6 (with echo).
Disconnect Mode
In disconnect mode, DTR drop can be activated or ignored to end a connection:
- Disconnect with DTR drop:
80
- Ignore DTR:
00
Force Telnet Mode
With another bit in the disconnect mode, the VMSE can be forced into Telnet
(terminal) mode and the setup for the terminal name can be enabled:
- activate Telnet mode and terminal type setup:
40